INTRODUCTION
BRUCE SPECIAL COPY
Instructions to Installer
1.Installer must leave instruction manual with owner after installation.
2.Installer must have owner fill out and mail warranty card supplied with unvented room heater.
3.Installer should show owner how to start and operate unvented room heater.
Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of an unvented room heater.
This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.
This appliance is only for use with the type of gas indicated on the rating plate.
WARNING: ANY CHANGE TO THIS HEATER OR ITS CONTROLS CAN BE DANGEROUS.
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater.
General Information
This unvented heater is design certified in accordance with American National Standards Institute Z21.11.2 by the Canadian Standards Association as an Unvented Room Heater and should be installed according to these instructions.
Attention: During initial use of ceramic log you will detect an odor as the ceramic log is cured. Also, during the curing process the ceramic log will burn with a yellow flame.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change.
Important
All correspondence should refer to complete Model Number, Serial Number and type of gas.
Notice: During initial firing of this unit, its paint will bake out, and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the unit is installed.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas- sachusetts.
Sellers of unvented propane or natural
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54.*
*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.
High Altitudes
For altitudes/elevations above 2,000 feet (610m), ratings should be reduced at the rate of 4 percent for each 1,000 feet (305m) above sea level. Contact the manufacturer or your gas company before changing spud/orifice size.
Well Head Gas Installations
Some natural gas utilities use "well head" gas. This may affect the Btu output of the unit. Contact the gas company for the heating value. Contact the manufacturer or your gas company before changing spud/orifice size.
WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.
SPECIFICATIONS
|
|
|
|
|
|
|
| Model |
| ||||
| Input BTU/HR (KW/H) |
|
|
|
|
|
| Max. (LP/NAT) | 25,000 ( 7.3) |
| 25,000 (7.3) | 25,000 ( 7.3) |
|
| Medium |
| 20,000 (5.9) | |||
| Min. (LP/NAT) | 17,500 (5.1) |
| 15,000 (4.4) | 17,500 (5.1) |
|
| Height | 26 3/4" (679mm) |
| 26 3/4" (679mm) | 26 3/4" (679mm) | |
| Width | 26 1/4" (666mm) |
| 26 1/4" (666mm) | 26 1/4" (666mm) | |
| Depth | 17 1/8" (434mm) |
| 17 1/8" (434mm) | 17 1/8" (434mm) | |
| Gas Inlet | 3/8" (9.5mm) |
| 3/8" (9.5mm) | 3/8" (9.5mm) | |
| Stove Casting (Requires |
|
|
| ||
|
|
| ||||
| Accessories for |
|
|
|
|
|
| TMV | Wall Thermostat, Millivolt |
|
| ||
| FRBC | Battery Operated Remote Control |
|
|
| |
| FRBTC | Battery Operated Remote Control with Thermostat |
|
| ||
| FREC | Electric Remote Control |
|
|
| |
| Wall Switch |
|
|
| ||
|
|
|
|
|
|
|
Page 5 |