GAS SUPPLY

BRUCE SPECIAL COPY

Check all local codes for requirements, especially for the size and type of gas supply line required.

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

Recommended Gas Pipe Diameter

 

 

 

 

 

 

Pipe Length

Schedule 40 Pipe

Tubing, Type L

 

(Feet)

Inside Diameter

Outside Diameter

 

 

Nat.

L.P.

Nat.

L.P.

 

0-10

1/2"

3/8"

1/2"

3/8"

 

 

12.7mm

9.5mm

12.7mm

9.5mm

 

10-40

1/2"

1/2"

5/8"

1/2"

 

 

12.7mm

12.7mm

15.9mm

12.7mm

 

40-100

1/2"

1/2"

3/4"

1/2"

 

 

12.7mm

12.7mm

19mm

12.7mm

 

100-150

3/4"

1/2"

7/8"

3/4"

 

 

19mm

12.7mm

22.2mm

19mm

 

 

 

 

 

 

 

Figure 1

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

A gas valve and ground joint union should be installed in the gas line upstream of the gas control to aid in servicing. It is required 16937-4-0806

by the National Fuel Gas Code that a drip line be installed near the gas inlet. This should consist of a vertical length of pipe tee connected into the gas line that is capped on the bottom in which condensation and foreign particles may collect.

Method of Installing a Tee Fitting Sediment Trap

The use of the following gas connectors is recommended:

ANS Z21.24Appliance Connectors of Corrugated Metal Tubing and Fittings

ANS Z21.45Assembled FlexibleAppliance Connectors of Other

Than All-Metal Construction

The above connectors may be used if acceptable by the authority having jurisdiction.The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

Pressure Testing of the Gas Supply System

1.To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance.

2.The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).

3.The appliance must be isolated from the gas supply piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).

Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition.

Checking Manifold Pressure

VFCR-25 Natural gas will have a manifold pressure of approximately 3.5" w.c. (.871kPa) for maximum input or 1.7" w.c. (.423kPa) for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.614kPa). VFCM-25 and VFCT-25 Natural gas will have a manifold pressure of approximately 6.0" w.c. (1.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 7.0" w.c. (1.74kPa) for the purpose of input adjustment to a maximum of 10.5" w.c. (2.615kPa). VFCR-25 Propane gas will have a manifold pressure approximately 10.0"w.c. (2.49kPa) for maximum input or 6.3"w.c. (1.568kPa) for minimum input at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa). VFCM-25 and VFCT-25 Propane gas will have a manifold pressure approximately 10.0"w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0"w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0"w.c. (3.237kPa).

NOTE: The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

A test gauge connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch 3mm) N.P.T. plugged tapping.

Page 7

Page 7
Image 7
Empire Comfort Systems VFCM-25-3. VFCR-25-3, VFCT25-3 installation instructions GAS Supply, Bruce Special Copy

VFCT25-3, VFCM-25-3. VFCR-25-3 specifications

Empire Comfort Systems has long been recognized for its commitment to delivering high-quality heating products that cater to a variety of residential and commercial needs. Among their offerings, the VFCM-25-3, VFCR-25-3, and VFCT-25-3 stand out as exceptional models in the realm of vent-free gas fireplaces. These units are designed to provide warmth and comfort while boasting innovative technologies, efficiency, and user-friendly features.

The VFCM-25-3 model is particularly notable for its contemporary design, offering a sleek appearance that can complement various home decors. It utilizes a dual fuel system, allowing it to run on both natural gas and propane. This flexibility ensures that users have options based on their heating preferences and availability of fuel sources. The in-built thermostat control enables automatic adjustments to maintain a consistent temperature, providing comfort without the need for constant monitoring.

Meanwhile, the VFCR-25-3 model focuses on efficiency and an elegant, traditional style. It incorporates Empire's cutting-edge technology that allows for a quick and efficient heat production. Featuring a unique safety pilot system, the VFCR-25-3 automatically shuts off the gas supply in case of a malfunction, ensuring peace of mind for homeowners. Additionally, this model is equipped with a ceramic burner that produces realistic flame patterns, creating a warm ambiance in spaces of various sizes.

The VFCT-25-3 variant is designed with versatility and user convenience in mind. This model comes with vent-free technology that allows for installation in locations where venting would be challenging or impossible. Its adjustable flame height allows users to customize the experience, creating a customizable ambiance that caters to personal preferences. Moreover, the unit is equipped with a built-in oxygen depletion sensor (ODS) that ensures safe operation by shutting off the unit if oxygen levels drop to unsafe levels.

All three models share common features like easy installation, thermal efficiency, and low emissions, making them environmentally friendly options. They are perfect for both supplemental and primary heating, providing comfort during the cold winter months without the need for extensive alterations to existing structures. Empire Comfort Systems continues to lead the market with innovative solutions that prioritize warmth, safety, and aesthetic appeal. Whether you choose the VFCM-25-3, VFCR-25-3, or VFCT-25-3, you can be assured of quality comfort and reliability for years to come.