Empire Products EE-25-2 installation instructions Clearances, Combustible Material, Figure Figure

Models: EE-25-2

1 16
Download 16 pages 11.37 Kb
Page 8
Image 8
CLEARANCES

CLEARANCES

When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.

Left side 5 inches (127mm). Right side 5 inches (127mm). Do not install in alcove or closet.

Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm).

Provide adequate clearances around air openings.

Adequate accessibility clearances for purposes of servicing and proper operation must be provided.

Figure 3

Figure 4

 

COMBUSTIBLE MATERIAL

Do not attach combustible material to the mantel of your fireplace. This is a fire hazard.

No greeting card, stocking or ornamentation of any type should be placed on or attached to the fireplace. This is a heating appliance. The flow of heat can ignite combustibles.

Figure 5

Figure 6