Outside Combustion Air Supply

The Ener-Radiant XL heater is approved for installation with an outside air supply system. Some compounds such as halogenated hydrocarbons or other corrosive chemicals in the air can be drawn into the equipment and cause an accelerated rate of corrosion of some of the heater components. The use of such chemical compounds near the enclosure should be avoided.

IMPORTANT: If the building has a slight negative pressure or contaminants are present in the air, an outside combustion air supply to the heaters is strongly recommended.

For an outside air supply, a four (4”) inch O.D. single wall pipe may be attached to the heater. The duct may be up to forty-five (45’) ft. maximum length or two (2’) ft. minimum length with no more than two (2) elbows. (See General Requirements in page 21 for additional information.) An outside air supply should not be used with the draft hood venting configuration.

The air supply duct may have to be insulated to prevent condensation on the outer surface. The outside air terminal should be securely fastened to the outside wall by drilling four (4) 1/4” diameter holes in the outside flange; wood screws or bolts and expansion sleeves may be used to fasten terminal.

FIGURE 16: Non-Pressurized Outside Air Supply Duct

Outside Air Terminal: Use ACME #104 Enerco Stk. #19030.

PVC Pipe, “Dryer Hose”, or equivalent may be used instead of standard vent pipe.

Section 6

Gas Piping

Read applicable warnings in (Section 1) before proceeding with Gas Pipe installation. Improper installation may result in property damage, severe injury, or death.

Meter and service must be large enough to handle all the burners being installed plus any other connected load. The gas line which feed the system must be large enough to supply the required gas with a maximum pressure drop of 1/2” water column. When gas piping is not included in the layout drawing, the local gas supplier will usually help in planning the gas piping.

A 1/2” tapping at each burner location must be located and oriented as shown in (Figure 17). To check system pressure, put a plugged 1/8” NPT tapping in the gas line at the connection to the burner farthest from the supply. Before connecting the burners to the supply system, verify that all high pressure testing of the gas piping has been completed. Do not high pressure test the gas piping with the burners connected.

Follow these instructions to ensure a professional gas supply installation:

Support all gas piping with suitable pipe hanging materials.

Use wrought iron or wrought steel pipe and malleable iron fitting. All pipe fittings should be new and free from defects. Carefully ream the pipe and tubing ends to remove obstructions and burrs.

Use L.P. gas-resistant joint compound on all pipe threads.

Check the pipe and tubing ends for leaks before placing heating equipment into service. When checking for gas leaks, use soap and water solution:

NEVER USE AND OPEN FLAME.

Install the flex gas connector as shown. The flex gas connector accommodates expansion of the heating system and allows for easy installation and service of the burner.

FIGURE 17: Gas Line Connection with Stainless Steel Flex Gas Connector

Shut – off Valve

Shut-Off Valve must be parallel

to burner gas inlet. The 2”

 

 

displacement shown is for the cold

 

condition. This displacement may

2"

reduce when the system is fired.

12"

 

 

 

1/2" Stainless Steel Flex Gas Connector

 

 

Stk. #16401

45°

45°

 

 

 

 

90°

 

Enerco enerRadiant® XL Series Heater

19

Operating Instructions and Owner’s Manual

Page 19
Image 19
Enerco ERXL-100 Section Gas Piping, Outside Combustion Air Supply, Shut-Off Valve must be parallel, To burner gas inlet

ERXL-125S, ERXL-100S, ERXL-150L, ERXL-60, ERXL-175 specifications

Enerco has made significant advancements in heating solutions with its lineup of powerful and efficient models: the ERXL-175L, ERXL-80, ERXL-125, ERXL-80S, and ERXL-100. Each model offers unique features tailored to various heating requirements while ensuring reliability and performance.

The ERXL-175L stands out as a high-capacity unit designed for larger spaces. With an impressive output of 175,000 BTUs, it is perfect for industrial applications or large workshops. This model is equipped with a robust heating element that provides quick and efficient heat distribution. Its built-in safety features, including overheat protection and flame failure detection, ensure safe operation even in demanding conditions.

The ERXL-80 is a mid-range model with an output of 80,000 BTUs, making it ideal for medium-sized spaces like garages and smaller warehouses. This unit features advanced electronic ignition and adjustable thermostat control, allowing users to easily customize heating levels based on specific needs. Additionally, its lightweight design facilitates easy installation and portability.

For those needing slightly more power, the ERXL-125 offers 125,000 BTUs of heating strength. This model combines efficiency with versatility. It features a durable, corrosion-resistant casing that enhances longevity, making it suitable for outdoor use. The ERXL-125 also includes a user-friendly control panel, offering intuitive operation for users of all experience levels.

The ERXL-80S is designed with mobility in mind. Similar in output to the ERXL-80, but with added features for dynamic heating solutions, this model is perfect for job sites where mobility is paramount. It boasts heavy-duty wheels for easy transportation and a robust heating mechanism suitable for both indoor and outdoor applications. The ERXL-80S also includes a protective grill to enhance safety during use.

Lastly, the ERXL-100 provides a balance between efficiency and power with an output of 100,000 BTUs. This model incorporates modern technology, such as an automatic ignition system and an energy-efficient combustion process, allowing for lower fuel consumption without sacrificing performance. Additionally, it features an ergonomic design that allows for hassle-free handling and maneuverability.

In summary, Enerco's ERXL series models, including the ERXL-175L, ERXL-80, ERXL-125, ERXL-80S, and ERXL-100, provide a range of heating solutions suited for various applications. Each unit features advanced technologies, safety mechanisms, and user-friendly designs that enhance operational efficiency and reliability, making them excellent choices for anyone in need of robust heating solutions.