Assemble the heater components as shown in Figures 2a, 2b, 2c, 2d, 2e, and 2f. Optional reflector configurations are shown in (Figure

1). Install appropriated suspension hardware, beam clamps, chain or rod at predetermined locations. Adjustment of chain length will provide uniform pitch.

Couplings: Tube and tube fittings are connected by wrap-around couplings which clamp by means of a tapered, hammer-driven lock member. The starting ends of the coupling and lock member are identified by 1/4” holes which are put together when starting assembly. Be sure the tube ends are in line and tube ends butt against stop pin(s) inside coupling. The slide bar is to be hammer-driven to a point of securing the coupling snugly to the tubes. Over-driving will result in distortion of the coupling or slide bar lip to a point decreasing the holding the capability of the coupling. Coupling should be tight when the slide bar is +- 2” from the end of the coupling.

(See Figure 3)

3)Attach the wire to the hole in the tab on the adapter piece.

4)Using the wire, pull the assembled turbulator into the tube from the opposite side.

5)Pull the turbulator through until just the tab comes out. Detach the wire.

6)Bend the tab around the tubing. When installing the tube, the tab will be locked in place by the adapter.

FIGURE 4: Installation of Elbow & Coupling (optional equipment)

Elbow Package:

Stk. # F106415 Elbow Package includes:

 

(1) elbow, (1) coupling and (1) refelctor.

 

Install elbow into radiant tube sequence

 

where plans indicate a 90° bend

 

(see Figure 4).

 

 

 

 

FIGURE 3: Coupling Assembly

Loosen

Orient coupling so that

the impact block is above

tube centerline.

Elbow Fitting Dimensions

90° Elbow

e

Tighten

Hole 1

 

 

Hole 2

 

Impact

 

Block

 

Coupling

 

Assembly

When assembling coupling note the location of Hole 1 and Hole 2

Plain Coupling - 14612

TURBULATOR BAFFLE ASSEMBLY INSTRUCTIONS

For ease of field installation, the turbulator should be installed in the tube before hanging the system.

Use the following procedure:

1)Assemble turbulator pieces by “twisting” matching ends together.

2)Insert a long wire (11 ft. minimum) down the length of the tube.

Stk. # F106414 U-Tube Package includes:

(1) U-tube, (1) coupling and (2) reflectors. Install U-tube elbow into radiant tube sequence where plans indicate a 180° bend

(see Figure 4).

U-Tube Fitting Dimensions

180° U-Tube

Enerco enerRadiant® XL Series Heater

14

Operating Instructions and Owner’s Manual

Page 14
Image 14
Enerco ERXL-80S, ERXL-175L, ERXL-60, ERXL-150L, ERXL-125S, ERXL-100S owner manual Plain Coupling

ERXL-125S, ERXL-100S, ERXL-150L, ERXL-60, ERXL-175 specifications

Enerco has made significant advancements in heating solutions with its lineup of powerful and efficient models: the ERXL-175L, ERXL-80, ERXL-125, ERXL-80S, and ERXL-100. Each model offers unique features tailored to various heating requirements while ensuring reliability and performance.

The ERXL-175L stands out as a high-capacity unit designed for larger spaces. With an impressive output of 175,000 BTUs, it is perfect for industrial applications or large workshops. This model is equipped with a robust heating element that provides quick and efficient heat distribution. Its built-in safety features, including overheat protection and flame failure detection, ensure safe operation even in demanding conditions.

The ERXL-80 is a mid-range model with an output of 80,000 BTUs, making it ideal for medium-sized spaces like garages and smaller warehouses. This unit features advanced electronic ignition and adjustable thermostat control, allowing users to easily customize heating levels based on specific needs. Additionally, its lightweight design facilitates easy installation and portability.

For those needing slightly more power, the ERXL-125 offers 125,000 BTUs of heating strength. This model combines efficiency with versatility. It features a durable, corrosion-resistant casing that enhances longevity, making it suitable for outdoor use. The ERXL-125 also includes a user-friendly control panel, offering intuitive operation for users of all experience levels.

The ERXL-80S is designed with mobility in mind. Similar in output to the ERXL-80, but with added features for dynamic heating solutions, this model is perfect for job sites where mobility is paramount. It boasts heavy-duty wheels for easy transportation and a robust heating mechanism suitable for both indoor and outdoor applications. The ERXL-80S also includes a protective grill to enhance safety during use.

Lastly, the ERXL-100 provides a balance between efficiency and power with an output of 100,000 BTUs. This model incorporates modern technology, such as an automatic ignition system and an energy-efficient combustion process, allowing for lower fuel consumption without sacrificing performance. Additionally, it features an ergonomic design that allows for hassle-free handling and maneuverability.

In summary, Enerco's ERXL series models, including the ERXL-175L, ERXL-80, ERXL-125, ERXL-80S, and ERXL-100, provide a range of heating solutions suited for various applications. Each unit features advanced technologies, safety mechanisms, and user-friendly designs that enhance operational efficiency and reliability, making them excellent choices for anyone in need of robust heating solutions.