| Natural outlet pressure should be 3.5” | |
| LP inlet pressure should be 11.0” | |
| LP outlet pressure should be 10.25” | |
| 3. | Check for proper orifice and air plate. |
Burner Does Not | 1. Check ground wire continuity. | |
Stay Lit: | 2. | Check burner internal wiring for reversed |
| leads. | |
| 3. | Check insulation on the igniter leads. |
| 4. | Replace module if necessary. |
Honeywell Valve LED Status
The
FIGURE 22:
LED
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OFF | INDICATED | |||||||||||||
Off | No power to the control | |||||||||||||
Normal operation. | ||||||||||||||
| This indication shows whenever the system is | |||||||||||||
| powered, unless some abnormal event has occurred. | |||||||||||||
| Airflow providing switch remains closed longer than | |||||||||||||
30 |
|
|
|
|
| seconds after call for heat begins (air providing | ||||||||
switch |
|
|
|
|
| stuck closed.) | ||||||||
| Airflow providing switch remains open longer than 30 | |||||||||||||
| seconds after combustion air blower is energized - or | |||||||||||||
|
|
|
|
|
| blower does not energize. | ||||||||
White jumper wire is loose. | ||||||||||||||
Flame signal sensed out of proper sequence. | ||||||||||||||
System Lockout. |