Enerco ERXL-175L, ERXL-60, ERXL-80S Clearances To Combustibles, Reflector Type Position

Models: ERXL-125S ERXL-100S ERXL-150L ERXL-60 ERXL-175 ERXL-150 ERXL-100 ERXL-80S ERXL-125 ERXL-80 ERXL-175L

1 28
Download 28 pages 61.37 Kb
Page 6
Image 6

Clearances To Combustibles

TABLE 1: Minimum Clearances to Combustibles (Use Figure 1 on page 10 as a Guide)

Reflector Type

position

ERXL-60

ERXL-80

ERXL-100

ERXL-125

ERXL-150

ERXL-175

 

 

 

 

 

 

 

 

Standard Reflector

A

6”

6”

6”

6”

6”

8”

(Horizontal)

B

30”

36”

36”

36”

36”

36”

 

C

55”

55”

74”

87”

87”

87”

 

D

30”

36”

36”

36”

36”

36”

 

 

 

 

 

 

 

 

45° Reflector Tilt

A

12”

18”

18”

18”

18”

18”

 

B

30”

36”

36”

36”

36”

36”

 

C

55”

55”

74”

87”

87”

87”

 

E

36”

36”

36”

36”

36”

36”

 

F

60”

60”

60”

60”

60”

60”

 

 

 

 

 

 

 

 

U-Tube Standard

A

6”

6”

6”

6”

6”

8”

(Horizontal)

B

30”

36”

36”

36”

36”

36”

 

C

55”

55”

74”

87”

87”

87”

 

D

30”

36”

36”

36”

36”

36”

 

 

 

 

 

 

 

 

U-Tube Opposite 45°

A

12”

18”

18”

18”

18”

18”

 

B

30”

36”

36”

36”

36”

36”

 

C

55”

55”

74”

87”

87”

87”

 

F

60”

60”

60”

60”

60”

60”

 

 

 

 

 

 

 

 

U-Tube Full 45°

A

12”

18”

18”

18”

18”

18”

 

B

30”

36”

36”

36”

36”

36”

 

C

55”

55”

74”

87”

87”

87”

 

E

36”

36”

36”

36”

36”

36”

 

F

60”

60”

60”

60”

60”

60”

 

 

 

 

 

 

 

 

Unvented

Above A

36”

36”

36”

36”

36”

36”

 

 

 

 

 

 

 

 

Warning:

Fire or explosion hazard

Can cause property damage, severe injury or death.

In all situations, clearances to combustibles must be maintained. Failure to observe clearances to combustibles may result in property damage, severe injury, or death.

Minimum clearances must be maintained from vehicles parked below the heater. Signs should be posted in storage areas to specify maximum stacking height to maintain required clearances to combustibles.

Caution should be used when running the system near combustible materials such as wood, paper, rubber, etc. Consideration should be given to partitions, storage racks, hoists, building construction, etc.

TABLE 1 gives minimum acceptable clearances to combustibles. Clearances as shown in TABLE 1 are not for use in four-sided enclosures.

Enerco enerRadiant® XL Series Heater

6

Operating Instructions and Owner’s Manual

Page 6
Image 6
Enerco ERXL-80, ERXL-175L, ERXL-60 Clearances To Combustibles, Reflector Type Position, ERXL-100 ERXL-125 ERXL-150 ERXL-175