For a 2-wire control, use the TOTAL and COMMON connections on the heat pump pool heater wiring block.

Installing a Remote Control Device on Analog Heaters

Wiring

For a 2-wire control, use the TOTAL and COMMON connections on the heat pump pool heater wiring block.

For a 3-wire control, use the COMMON, SPA and POOL connections on the heat pump pool heater wiring block.

Installing a Remote Control Device on Digital Heaters

Wiring

For a 2-wire control, use the TOTAL and COMMON connections on the heat pump pool heater wiring block.

For a 3-wire control, use the COMMON, SPA and POOL connections on the heat pump pool heater wiring block.

Fig. 10: Heater Wiring Block — Analog Heaters

Heater Settings

1.To operate the heater using a 2-wireremote con- trol device, simply switch the Spa-Remote-Poolknob to the Remote position and make sure the heater is enabled on the remote control device.

2.To operate the heater using a 3-wireremote con- trol device, simply switch the Spa-Remote-Poolknob to the Remote position and set the tempera- ture for pool and spa.

Fig. 11: Heater Wiring Block — Digital Heaters

Heater Settings

1.Make sure the heater is disabled on the remote control device. Then, push the SET key until POL is displayed. Push the DOWN arrow key until OFF is displayed. Wait until a temperature is displayed before beginning the next step.

2.Push the SET key until SPA is displayed, then push the UP arrow to 104°F. Wait until a tempera- ture is displayed before beginning the next step.

3.Push the SET key until P_S is displayed, then push the DOWN arrow until POL is displayed. Wait until a temperature is displayed before begin- ning the next step.

4.Finally, enable the heater on the remote control device. When there is a call for heat, the heater display will show SPA. When the heater is dis- abled, the display will show POL.