Page | 45
WARNING:ToavoidELECTRICALSHOCKalwaysdisconnecttheunitfromthepowersourceBEFORE
attemptinganyrepair.Ifthisguidedoesnotcorrecttheproblem,callyourlocaldealerorTechnical
Supportat1‐800‐245‐6489.
ProblemCause Solution
Augernotturning1.Badaugermotor.1.Replaceaugermotor.
2.Foreignmatterjamming
auger.
2.Removepelletsandobject.
3.Vacuumsensor.3.Checkexhaustblower.
Smokesmellordustin
house
1.Improperexhaustconnection.1.Checkexhaustconnectionsfor
leaks,especiallytheexhaust
blowerconnect.Sealleakswith
silicone,aluminumtapeorahose
clamp.
Roomblowernotoperating1.Loosethermalsensor.1.Tightenconnectiononsensor.
2.Blowerspeedsethigherthan
heatrange,causingstovetocool
andblowertocycle.
2.Lowerblowerspeed.
3.Looseconnection.3.Checkcontrolboard
connection.
Exhaustblowernot
operating
1.Looseconnection.1.Checkcontrolboard
connection.
2.Badblower.2.Replaceblower.
3.Badvacuumsensor.3.Replacevacuumsensor.
LazyFire1.Badexhaustblower.1.Inspectandreplaceblower.
2.Excessivepelletmoisture.2.Keeppelletsdry.
3.Excessiveashbuild‐up.3.Thoroughlycleanunit.
4.Lowqualitypellets.4.UseonlyPFIpremiumpellets.
BlownFuse1.Powersurge.1.Replacefuse;usesurge
protector.
2.Exposedwire.2.Checkforexposedorfrayed
wireandlooseconnections.
3.Electricalcomponentshorting.3.Checkmotorsandblowersfor
obstructionsorshortcircuits.
HighPelletConsumption1.Lowqualityornon‐uniformly
sizedpellets.
1.Usepremiumpelletsortry
anotherpelletbrand.
SqueakingNoise1.Obstructioninaugertube.1.Checkaugertubeforforeign
objects.
2.BlowerNoise.2.Remove,clean,andoilblower.
PingingorRattlingNoise
1.Foreignmaterialinblower.1.Checkbothblowersfor
material.