Enviro 1000 Model 1600 INS Fireplace Insert, Required Clearances to Combustibles from Insert

Models: 1600INS 1600 1000

1 19
Download 19 pages 47.38 Kb
Page 12
Image 12

MODEL 1600 INS FIREPLACE INSERT

Unless you are experienced, we recommend installation by your dealer or a professional installer.

Install only in a masonry fireplace at least 25” (635 mm) wide, 22” (560 mm) high and 14” (356 mm) deep with an approved lined chimney at least 15 ft (4.6 m) high, both of which have been constructed in accordance with the building code. Be sure the fireplace and chimney are clean and sound without any cracks or loose mortar. Do not remove any bricks or mortar from the fireplace.

1. Remove any fireplace damper or fasten in a permanent open position.

(IN CANADA)

2. The stove is vented with a 6” stainless steel liner that goes directly to the top of the chimney and is covered with a rain cap. The chimney top is sealed with a flashing or steel plate that supports the weight of the chimney liner. The installation must conform to the liners manufacturer’s instructions.

This fireplace must be installed with a continuous liner of 6” diameter (CANADA ONLY) extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the class 3 requirements of CAN/ULC-S635, standard for lining systems for existing masonry or factory built chimneys and vents, or CAN/ULC-S640, Standards for lining systems for new masonry chimneys.

(IN U.S.A.)

The appliance when installed, must follow local building codes, in the absence of local building codes, with the current NFPA 211 Standard for Chimneys, fireplaces, vents, and Solid Fuel Burning Appliances

Screw or Nail the metal plate provided form the manufacture to the inside of the fireplace.

METAL TAG: “THIS FIREPLACE HAS BEEN ALTERED TO ACCOMMODATE A FIREPLACE INSERT AND SHOULD BE INSPECTED BY A QUALIFIED PERSON PRIOR TO THE RE-USE AS A CONVENTIONAL FIREPLACE.”

REQUIRED CLEARANCES TO COMBUSTIBLES FROM INSERT:

Minimum clearances to a unshielded side wall: 17” (430 mm)

Minimum clearances to a unshielded mantle: 28” (710 mm)

Minimum top facing clearance: 28” (710 mm)

Minimum side facing clearance: 1” ( 25 mm)

If there is a combustible floor in front of the masonry fireplace, the fireplace insert must be 8” (205 mm) above the combustible floor, and floor protection must be provided 18” (455 mm) in front of the fireplace insert and 8 “(205 mm) to each side of the unit.

12

Page 12
Image 12
Enviro 1000, 1600INS manual Model 1600 INS Fireplace Insert, Required Clearances to Combustibles from Insert