OPTIONAL FAN INSTALLATION
The appliance when installed, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE. Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, or THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the USA.
CAUTION
Label all wires
prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
1)Remove the fan assembly from the box and inspect for any damage to the assembly.
2)Remove the metal knock out on the rear of the appliance.
3)Install two screws into the top two holes. Place the blower assembly over these two screws and tighten. Install the two bottom screws and tighten.
4)Plug the fan assembly in and check for proper operation.
DO NOT cut or remove the grounding prong from the plug. Also do not route the power cord beneath the heater.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS.
This appliance is equipped with a
WIRING DIAGRAM
This is a basic wiring diagram for the option fan installation. Models 1000, 1600, 2100 Freestanding units only.
1)Plug the fan assembly into a three prong (grounded) receptacle.
2)Turn the fan controller to the desired setting.
3)Once the unit has reached operating temperature, the fan temperature sensor will turn the fan on automatically.
4)When the unit cools down the fan temperature sensor will shut the fan off automatically.