DO NOT REMOVE THIS LABEL LISTED SOLID FUEL SPACE HEATER SERIAL NO.
MODEL: | 1000 | 1600 |
WH-
2100 | 1600 INS |
MODEL 1000 SUITABLE FOR USE IN MOBILE HOMES.
CERTIFIED FOR CANADA AND THE U.S.A. | REPORT NO. |
TESTED TO CSA | REPORT NO. 6385 |
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURERS INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. USE 6 IN. / 150 MM DIAMETER MINIMUM 24 MSG BLACK OR 25 MSG BLUED STEEL CONNECTOR LISTED
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATIONS USING SINGLE WALL CONNECTOR. WITH ANY
ANY UL 103 HT LISTED CHIMNEY SYSTEMS IN THE U.S.A.
|
| MODEL :1000 | MODEL: 1600 | MODEL: 2100 |
SIDE WALL TO UNIT | A | 19 IN. / 485 MM | 20 IN. / 510 MM | 22 IN. / 560 MM |
BACK WALL TO UNIT | B | 10 IN. / 255 MM | 12 IN. / 305 MM | 12 IN. / 305 MM |
CORNER TO UNIT | C | 6 IN. / 150 MM | 6 IN. / 150 MM | 8 IN. / 205 MM |
SIDE WALL TO CONNECTOR | D | 28 IN. / 710 MM | 29 IN. / 735 MM | 31 IN. / 790 MM |
BACK WALL TO CONNECTOR | E | 13 IN. / 330 MM | 16.5 IN. / 420 MM | 16.5 IN. / 420 MM |
CORNER TO CONNECTOR | F | 16 IN. / 405 MM | 16.5 IN. / /420 MM | 19 IN. / 485 MM |
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATIONS: MODELS 1000 AND 1600
IN CANADA: ANY
IN U.S.A.: ANY
SPECIFIED CLEARANCES APPLY AND UNITS MAY BE INSTALLED IN CONVENTIONAL HOMES IF SPECIFIED CONNECTORS ARE USED.
|
| MODEL 1000 | MODEL 1600 |
SIDE WALL TO UNIT | A | 14 IN./ 355 MM | 11 IN. / 280 MM |
BACK WALL TO UNIT | B | 6 IN. / 150 MM | 4 IN. / 101 MM |
CORNER TO UNIT | C | 2 IN. / 50 MM | 6 IN. / 153 MM |
SIDE WALL TO CONNECTOR | D | 23 IN. / 585 MM | 20 IN. / 508 MM |
BACK WALL TO CONNECTOR | E | 9 IN. / 230 MM | 8.25 IN. / 210 MM |
CORNER TO CONNECTOR | F | 11.5 IN. / 290 MM | 15.5 IN. / 394 MM |
MODEL 1000 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH, 4 FT. /1.22 M, HEIGHT 7 FT. 2.13 M
MODEL 1600 MAY BE INSTALLED IN AN ALCOVE: ALCOVE DEPTH 30” (76 CM) HEIGHT 70”(178 CM) WIDTH 48” (122 CM)
ROOM HEATER, SOLID FUEL TYPE, SUITABLE FOR MOBILE HOMES
If a stove is installed on a combustible floor, it must have a pedestal attached and be on a NON COMBUSTIBLE hearth pad extending at least 8” (200 mm) to each side, and 18” (455 mm) to the front
MODEL 1600 INS MAY BE INSTALLED AS AN INSERT IN A MASONRY
FIREPLACE.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS (MEASURE TO UNIT)
|
| MODEL 1600 INS |
ADJACENT SIDE WALL | A | 17 IN. / 430 MM |
MANTLE | B | 28 IN. / 710 MM |
TOP FACING | C | 28 IN. / 710 MM |
SIDE FACING | D | 1 IN. / 25 MM |
HEARTH EXTENSION MUST BE RAISED (F) 8 IN. / 205 MM ABOVE A SURROUNDING COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED BY A
455 MM TO THE FRONT OF THE UNIT AND (F) 8 IN. / 205 MM TO THE SIDES
OPERATE ONLY WITH THE DOOR AND ASH PAN CLOSED. ONLY OPEN DOOR TO FEED FIRE. FOR USE WITH SOLID WOOD FUELS ONLY. DO NOT USE GRATE OR
ROUTE CORD AWAY FROM HEATER.
MANUFACTURED BY: SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD RD.
VICTORIA B.C
MADE IN CANADA
CAUTION
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURN. READ NAMEPLATE AND INSTRUCTIONS.
16