Enviro 1000, 1600INS manual Freestanding Installation, Chimney

Models: 1600INS 1600 1000

1 19
Download 19 pages 47.38 Kb
Page 9
Image 9

FREESTANDING

INSTALLATION:

CHIMNEY:

Vent the stove into a clean, lined, approved masonry chimney in good condition, conforming to local building codes or a listed 6” factory built chimney suitable for use with solid fuels and conforming to, ULC-S629 in CANADA or UL- 103HT in the U.S.A.. Connect the stove to this chimney with a short and straight 6” (150 mm), 25 gauge or heavier, single wall black or blued steel smoke pipe. Connection to all masonry chimneys must be a metal or masonry thimble cemented in place. All smoke pipe must slope upwards, all connections must be tight and secured with three sheet metal screws equally spaced. The smoke pipe length should not exceed 40% of the chimney height above the stove.

A non-combustible floor protector is required under all freestanding units. The floor protection must extend 18” (457 mm) in front of the unit and 8” (203 mm) to each side. When venting into a masonry chimney the floor protector must be installed directly below the chimney vent and 2” (50.8 mm) on either side of the chimney vent.

DO NOT CONNECT THIS UNIT TO A

CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*

 

 

 

 

DOUBLE WALL

DOUBLE WALL

 

 

 

 

PIPE**

PIPE**

 

MODEL 1000

MODEL 1600

MODEL 2100

MODEL 1000

MODEL 1600

 

 

 

 

 

 

A. SIDE TO UNIT

19 “ (485 MM)

20” (510 MM)

22” (560 MM)

14” (355 MM)

11” (280 MM)

 

 

 

 

 

 

B. REAR TO UNIT

10” (2556 MM)

12” (300 MM)

12” (300 MM)

6” (150 MM)

4” (101 MM)

 

 

 

 

 

 

C. CORNER TO UNIT

6” (150 MM)

6” (150 MM)

8” (200 MM)

2” (50 MM)

6” (150 MM)

 

 

 

 

 

 

D. SIDE TO COLLAR

28” (710 MM)

29” (735 MM)

31” (790 MM)

23’ (585 MM)

20” (508 MM)

 

 

 

 

 

 

E. REAR TO COLLAR

13” (330 MM)

16.5” (420 MM)

16.5” (420 MM)

9” ( 230 MM)

8.25” (210 MM)

 

 

 

 

 

 

F. CORNER TO COLLAR

16” (405 MM)

16.5” (420 MM)

19 “ (485 MM)

11.5” (290 MM)

15.5” (394 MM)

 

 

 

 

 

 

CAUTION: AN UN INSULATED SMOKE PIPE MUST NOT PASS THROUGH AN ATTIC, ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR THROUGH A FLOOR, CEILING, WALL, OR PARTITION, OR ANY COMBUSTIBLE CONSTRUCTION.

*ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY.

**DOUBLE WALL: IN CANADA: ANY ULC-629 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING LISTED DOUBLE WALL VENT CONNECTOR.

IN U.S.A.: ANY HT-103 LISTED CHIMNEY SYSTEM WITH THE ACCOMPANYING

LISTED DOUBLE WALL VENT CONNECTOR.