Operating Instructions

For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating.

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY

RESULT, CAUSING PROPERTY DAMAGE, PERSONAL INJURY OF LOSS OF LIFE.

PILOT LIGHTING INSTRUCTIONS:

CAUTION:Hot while operating. Do not touch, severe burns may result.

Keep children, clothing, furniture, gasoline or other flammable vapors away.

CAUTION: Do not operate this fireplace with the glass removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified person! This appliance needs fresh air for safe operation and must be installed with provisions for combustion and ventilation air. See installation and operating instructions manual. Keep burner and control compartment clean.

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage, or loss of life. Refer to owner's manual provided with this appliance. See installation and operating instructions accompanying appliance. Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING

PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A)This appliance is equipped with a pilot, which must be lit by hand by following these instructions exactly.

B)BEFORE LIGHTING smell all around the appliance area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance. Do not touch any electrical switch: do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas suppliers instructions. If you cannot reach your gas supplier, call the fire department.

C)Use only your hand to push in or turn the gas control knob; NEVER use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D)Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this label.

2.Turn off all electrical power to this appliance.

3.Turn off the gas control knob clockwise to the off position.

4.Open door. Wait fIve (5) minutes to clear out any gas. Close door. If you smell gas STOP! Follow “B” in the above safety information.

If you do not smell gas go to the next step.

5.Find pilot-located to the left behind the side log.

Turn the gas control knob counter-clockwise to “PILOT”. Push the gas control in fully and hold, keep knob depressed for about 30 seconds after the pilot is lit. Release knob. If pilot goes out, repeat steps 4 through 5.

WARNING: This gas valve has a lockout device, which will not allow the pilot burner to be relit until the thermocouple has cooled. If the knob does does not pop up when released, stop and immediately call your service technician or gas supplier. If the pilot does not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician

or gas supplier.

6. Turn the gas control knob counter clockwise to the “ON” position.

Flip the burner switch to “ON” THEN

 

 

 

 

TURN THE “HI/LOW” knob to the

TP

 

OUT

IN

desired setting.

TH

H

O

 

7. Turn on the electrical power to the unit.

TP TH

I

L

OFF

 

 

 

 

LO

 

 

 

 

P

 

 

 

 

I

 

 

 

 

T

 

 

 

 

NO

 

 

P

 

 

 

 

TO LI

 

 

TO TURN OFF GAS TO APPLIANCE

1. Flip burner switch to “OFF”

 

3. Turn off all electrical power to the appliance if service is to be

2. Turn the gas control knob clockwise

to the “OFF” position.

performed.

Figure 2: Lighting Instruction Label.

1.Turn off the gas to the fireplace. If not recently done, remove the door and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING.

2.Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several times until the pilot light starts. Hold the gas control knob in for 30 seconds. Check that the pilot has fully engulfed the thermocouple assembly (refer to Figure 6).

3.Start the main burner by turning the gas control knob to ON and then turn the rocker switch to ON. Check that all burner ports have flame.

4. Leak test all gas joints again.

Figure 3: Pilot Assembly.

6

Page 6
Image 6
Enviro 50-1628 owner manual Operating Instructions, For Your Safety Read Before Operating

50-1628 specifications

Enviro 50-1628 is a revolutionary piece of technology designed to enhance sustainability and efficiency in various applications, particularly in the field of environmental management. This advanced system focuses on achieving ecological balance while delivering high performance, making it a valuable asset for industries aiming for greener operations.

One of the main features of the Enviro 50-1628 is its cutting-edge filtration technology. The system utilizes multi-stage filtering mechanisms that purify air and water, effectively removing pollutants and contaminants. This is accomplished through a combination of mechanical, chemical, and biological processes, ensuring that the output meets or exceeds regulatory standards. The efficiency of the filtration system plays a crucial role in reducing environmental impact by minimizing harmful emissions and discharges.

Another notable characteristic of the Enviro 50-1628 is its intelligent monitoring capabilities. Equipped with advanced sensors, the system continuously collects data on environmental parameters such as air quality, temperature, and humidity. This real-time data is processed through sophisticated algorithms, enabling proactive adjustments to optimize system performance. This not only improves the efficiency of operations but also allows for timely interventions to prevent potential environmental hazards.

In terms of energy efficiency, the Enviro 50-1628 is designed with sustainability in mind. It incorporates renewable energy sources, such as solar panels, to power its systems, significantly reducing dependency on fossil fuels. Moreover, its modular design allows for easy scalability, enabling facilities to expand their capacity while maintaining energy efficiency and reducing carbon footprints.

The Enviro 50-1628 is also user-friendly, featuring an intuitive interface that allows operators to easily monitor and control various functions. This accessibility is crucial for promoting best practices in environmental management, ensuring that organizations can effectively implement and adhere to sustainability initiatives.

Furthermore, the Enviro 50-1628 is built with durability in mind, utilizing high-quality materials to ensure long-lasting performance even in demanding environments. This resilience not only extends the lifespan of the system but also reduces maintenance costs, making it a cost-effective solution for businesses committed to sustainable practices.

In summary, the Enviro 50-1628 stands out as a powerful tool in the pursuit of environmental sustainability. Its advanced filtration technology, intelligent monitoring systems, energy efficiency, user-friendly interface, and durable construction make it an excellent choice for industries looking to minimize their ecological footprint while maximizing operational efficiency. By integrating such technologies, organizations can take significant strides towards a greener future.