Troubleshooting

üCheck the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting).

– Replace the Circuit Board if the Voltage reading is less than 82V. with a line voltage >115Vac.

üCheck Vacuum levels in the exhaust channel by bypassing the Vacuum Switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge (readings must be above .10” W.C. on low fire).

If the motor fails to reach a 0.10” w.c. readings, then replace the Combustion Blower.

üPoor Quality Fuel – Insufficient energy in the fuel to produce enough heat to keep the stove burning or operational.

üExhaust Temperature Sensor failure. – Bypass sensor located on Exhaust Blower if stove now operates properly, the unit may require cleaning or a new sensor. Contact your local dealer for service.

The exhaust motor will not function normally

üOpen the left side access panel; check all connections against the wiring diagram.

üSee above section.

Light # 2 on Heat output bar flashing – The Vacuum Switch contacts have opened for more than 15 sec.

üPinch, break or blockage in Vacuum Hose - Check hose for pinch points or damage, replace or re-route as required. Blow out Vacuum Hose

üBlocked Hose Barb on Exhaust Channel - Use a paper clip to clean out Hose Barb or remove the Vacuum Hose from the Vacuum Switch and blow into the hose to remove blockage.

üBlocked exhaust / venting system - Have stove and venting cleaned and inspected.

üSevere negative pressure in area where unit is installed - Check the operation by opening a window, does this solve the problem? If it does, install fresh air intake to unit or room. Venting system may require vertical section to move termination into a low pressure zone.

üVacuum Switch failure - Bypass the vacuum switch, if this corrects the problem check for above problems before replacing the Vacuum Switch.

üDamage to gray wires between Circuit Board and Vacuum Switch - Inspect wires and connectors

üCombustion Blower failure - The Combustion Blower is not turning fast enough to generate the proper vacuum in the Exhaust Channel. Visual Check; is the blower motor turning? Check the Exhaust Blower voltage across the blower wires (>=114V on #5 setting and >= 82V on #1 setting). Replace the Circuit Board if the Voltage reading is less than 82V. with a line voltage >115Vac.

üCheck Vacuum levels in the exhaust channel by bypassing the vacuum switch, then remove the Vacuum hose from Vacuum Switch. Check exhaust vacuum readings by placing the open end of the Vacuum Hose on a Magnahelic Gauge. (readings must be above .10” W.C. on low fire).

If the motor fails to reach a 0.10” w.c. readings, then replace the Combustion Blower

To reset Circuit Board after a trouble code - push the ON/OFF button

30

Page 30
Image 30
Enviro C-10135 owner manual Exhaust motor will not function normally

C-10135 specifications

Enviro C-10135 is a cutting-edge solution that has emerged to address the growing concerns in environmental management and sustainability. Designed to meet the demands of modern industries, it incorporates a wide array of features and technologies that set it apart in the field.

One of the standout characteristics of Enviro C-10135 is its innovative waste management capabilities. The system employs advanced sorting and recycling technologies that enable efficient separation of contaminants from recyclable materials. This not only streamlines the recycling process but also significantly reduces the volume of waste sent to landfills. With a focus on circular economy principles, Enviro C-10135 helps industries adopt more sustainable practices while minimizing their environmental footprint.

The technology behind Enviro C-10135 is grounded in real-time data analytics. Integrated sensors monitor environmental conditions and waste composition continuously. This data is processed using advanced algorithms that provide actionable insights for waste management strategies. As a result, users can optimize operational efficiency, reduce costs, and enhance compliance with regulatory requirements.

Another key feature of Enviro C-10135 is its adaptability. The system can be customized to fit the specific needs of various industries, ranging from manufacturing to hospitality. Manufacturers can modify its settings to handle different types of waste, while facilities in the hospitality sector benefit from tailored solutions for food waste and packaging materials. This versatility makes Enviro C-10135 an attractive choice for businesses of all sizes.

Energy efficiency is also a salient characteristic of the Enviro C-10135. The system is engineered to minimize power consumption without compromising performance. It employs energy recovery technologies that harness excess energy generated during waste processing, which can be redirected for operational needs. This aspect not only lowers operational costs but also contributes to sustainability goals.

In addition to its technological prowess, Enviro C-10135 is user-friendly. The interface is designed to provide intuitive navigation for operators, easing the learning curve and ensuring efficient operation. Training programs and support are also available to assist users in maximizing the system's potential.

In summary, Enviro C-10135 is at the forefront of environmental technology, offering advanced waste management features, real-time monitoring and analytics, adaptability for various applications, energy efficiency, and user-friendly operation. As industries strive to meet sustainability targets, Enviro C-10135 stands as a vital asset in achieving these goals and fostering a cleaner, more sustainable future.