Enviro C-11023 Install vent at clearances specified by the vent manufacturer, Installation, 7.5cm

Models: C-11023

1 36
Download 36 pages 21.74 Kb
Page 13
Image 13
Back Wall

Installation

CLEARANCES TO COMBUSTIBLES:

This unit can be installed on a combustible floor when installed with the optional hearth pad part EF5-103 (for example linoleum, hardwood flooring). If this unit is to be installed onto a carpeted surface, a hearth pad must be used for stability.

 

Back Wall

3"

 

3" (7.5cm)

 

(7.5cm)

 

 

Wall

6"

 

Side

 

(15cm)

 

 

 

Figure 6: EF5 Clearance to Combustibles.

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for serving, routine cleaning and maintenance.

Side wall to unit

6 inches

(15 cm)

Back wall to unit

3 inches

(7.5 cm)

Corner to unit

3 inches

(7.5 cm)

ALCOVE CLEARANCES:

This unit may be installed in an alcove. Maintain these clearances to combustibles.

Minimum Alcove width

48 inches (122 cm)

Minimum Alcove height

48 inches

(122 cm)

Maximum Alcove depth

48 inches

(122 cm)

Install vent at clearances specified by the vent manufacturer.

48"

(122cm)

48"

(122cm)

48"

(122cm)

Figure 7: EF5 Minimum Alcove Size.

13

Page 13
Image 13
Enviro C-11023 Install vent at clearances specified by the vent manufacturer, Installation, Back Wall, 3 7.5cm, Side, 15cm