Enviro DV42DX owner manual Initial Installation, Qualified Installers Only

Models: DV42DX

1 39
Download 39 pages 52.34 Kb
Page 12
Image 12
Initial Installation

Initial Installation

QUALIFIED INSTALLERS ONLY

INTRODUCTION:

This section of the owner’s manual is for the use of qualified technicians only. Fireplace placement, hearths, facings, mantels, and venting terminations will be covered, as well as the gas and electric systems. There are several installation safety guidelines that must be adhered to. Please carefully read the safety precautions at the front of this manual.

PLACEMENT:

The location for the fireplace can be along a wall, raised or at floor level, or in a corner. There are specific framing measurements for each situation. The basic opening should have the dimensions shown below in Figure 10.

Warning: Clearances must be sufficient to allow access for maintenance and service.

 

 

 

 

 

 

41 1/4"

 

 

 

 

 

 

(1046mm)

 

 

 

 

 

Gas Line

 

 

"

 

 

 

 

 

2

 

 

 

 

1/

 

)

 

 

9

 

 

 

 

 

m

 

 

1

 

m

 

 

 

 

4

 

 

 

 

49

 

 

 

 

(

 

 

 

 

 

 

 

 

 

 

"

)

 

 

 

 

2

 

 

 

 

 

4

 

m

 

 

 

 

 

m

 

 

 

 

7

 

Electrical Line

 

 

 

6

 

 

 

 

0

 

 

 

 

 

(1

 

 

Figure 10. Dimensions for Framing the Firebox.

The fireplace must have a strong and level surface to be placed on. The surface should be made of wood or a non- combustible material, not carpet.

The 191⁄2 inches (494 mm) dimension takes into account the 1 inch (25 mm) standoff on the back of the firebox. The framing boards may touch the standoffs, but no insulating material can be placed between the frame and the standoffs.

The gas line, 3/8” NPT, should be brought to the right side of the fireplace. If this set up is inconvenient, the electrical wire and the gas line configuration can be reversed.

The location should be chosen so the fireplace will be at least 36 inches (914

mm)from drapes, doors and other combustibles. The fireplace opening should also be at least 5 inches (127

mm)from the nearest perpendicular wall (sidewall to the edge of the opening).

12

Page 12
Image 12
Enviro DV42DX owner manual Initial Installation, Qualified Installers Only