Figure 6. Control Panel

Operating Instructions

BURNER LIGHTING:

A)Make sure the pilot is lit.

B)Turn gas control knob COUNTER CLOCKWISE to ON.

C)Flip the burner switch to ON.

D)Turn HI/LO knob to the desired flame height.

E)Turn on all electrical power to the unit.

NOTE: Check that all burner holes are lit.

TO TURN GAS FIREPLACE OFF

Flip switch to OFF to turn off burners only.

If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. DO NOT

FORCE IT. If the unit is going to be serviced, turn off the electrical power to the unit as well.

NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first four (4) hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See MAINTENANCE AND SERVICE - CLEANING THE

GLASS and MAINTENANCE AND SERVICE - GLASS DOOR REMOVAL.

REMOTE CONTROLS:

This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines.

BLOWER SPEED:

The blower will come on only when the fireplace is up to temperature (approximately 20 minutes). The speed of the fan can be changed by turning the fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE until it “clicks” off (Figure 7).

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the windings of the blower and running the blower at lower speeds could also cause premature fan failure.

NORMAL SOUNDS DURING OPERATION:

��

���

��

Figure 7. Fan Control

 

Table 1: Normal Sounds

 

 

Component

Sound & Reason

 

 

DV42DX & Fascia

Creaking when heating up or cooling down.

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

 

 

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

8

Page 8
Image 8
Enviro DV42DX owner manual To Turn GAS Fireplace OFF, Component Sound & Reason

DV42DX specifications

The Enviro DV42DX is a highly efficient and eco-friendly ventilation device designed to enhance indoor air quality while minimizing energy consumption. This powerful product is tailored for residential and commercial applications, making it a versatile choice for those looking to improve air circulation.

One of the standout features of the Enviro DV42DX is its dual-speed fan system, which allows users to select the optimal airflow needed for various conditions. This not only provides flexibility but also contributes to energy efficiency, as it can operate at lower speeds during quieter periods. The adjustable fan settings ensure that users can tailor the device’s performance to meet their specific requirements.

Incorporating advanced filtration technologies, the Enviro DV42DX features an integrated HEPA filter that effectively captures airborne particles, allergens, and pollutants. This makes it an ideal choice for individuals with allergies or respiratory conditions, as it significantly reduces exposure to harmful elements in the air. Additionally, the unit is equipped with a charcoal filter that helps eliminate odors, further enhancing the indoor atmosphere.

The Enviro DV42DX is designed with user convenience in mind. It includes a programmable timer and a remote control, allowing users to operate the device from a distance and set it on a schedule that aligns with their routines. This feature not only enhances the ease of use but also encourages energy-saving habits by allowing the unit to operate only when needed.

Another characteristic of the Enviro DV42DX is its energy-efficient design, boasting a high Energy Star rating. The device not only reduces energy consumption but also saves users money on utility bills over time. Its durable construction and high-quality materials ensure longevity and reliable performance, making it a wise investment for maintaining a healthy living or working environment.

Safety is also a top priority for the Enviro DV42DX. The unit is equipped with built-in sensors that monitor air quality and automatically adjust operation to ensure optimal performance. This smart technology ensures that the device operates efficiently while maintaining safe levels of indoor air quality.

In conclusion, the Enviro DV42DX offers an impressive array of features and technologies that prioritize indoor air quality and energy efficiency. Its combination of advanced filtration, user-friendly controls, and smart technology makes it an indispensable tool for any environment aiming for cleaner and healthier air. Investing in the Enviro DV42DX is a step toward a more sustainable and comfortable indoor atmosphere.