INSTALLATION INSTRUCTIONS:

Initial Installation

QUALIFIED INSTALLERS ONLY

INSTALLATION INSTRUCTIONS:

1.Plan your installation and clearances to combustibles. Decide on a location for the unit that will meet the clearances noted in the venting section, and any or all local code requirements.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are in the way of the venting system as it passes through the exterior wall. The fireplace location should be adjusted if obstructions are found in the wall.

3.Project a line from the center point of the flue outlet upward and outward to the desired flue outlet location on the exterior wall. Using this center point, scribe a 10” (25.4 cm) hole or square on the

wall. Cut the hole from the interior through

����

the exterior wall surfaces.

�������

4. Frame the hole as shown in Figure 24.

 

5.Trim the wall thimble to match the wall thickness as necessary. Install the wall

thimble and secure it to the inner wall

frame using four (4) 11⁄2” wood screws. If

a wall is greater than 8” (203mm) in depth,

the clearance above the flex must be 43⁄8”

(111mm)

Figure 21: Wire Spacer in Place.

 

Figure 20: Wire Spacers.

Horizontal Vent Termination

 

6. Apply a bead of Mill-Pac Black

 

sealant to the new Ø4” (10 cm) by

 

5” (12.5 cm) provided flue collar

 

adaptor. Press the flue collar into

 

the flue outlet of the fireplace so

 

that the Mill-Pac seals the flue

 

collar to the flue outlet.

 

7. Stretch both the Ø4” (10 cm) flex

Wall Framing

vent and the Ø65⁄8” (16.25 cm) flex

Wall Thimble

intake liner to the length needed

Fire Stop

 

to ensure the flex can be easily

Exhaust 4" Flex Pipe

connected to the vent terminal.

 

8. Slide the Ø65⁄8” (16.25 cm) flex

 

intake liner over the flex vent.

Wire Spacers

Install four (4) wire spacers

 

around the flex pipe. Ensure the

 

wire spacers are positioned at

 

either end of the pipes, and at

Combusion Air 6 5/8" Flex Pipe

each end of any elbows in the

 

liners (refer to Figure 20 and 21).

 

9. Install the flex pipe assembly

Flue Pipe Adaptor

through the wall thimble, ensure

 

that this portion of pipe slides

Figure 22: Installation of Fireplace Horizontal Vent Kit.

17

Page 17
Image 17
Enviro DV42DX owner manual Initial Installation, Qualified Installers Only, Installation Instructions