CLEARANCES TO COMBUSTIBLES

CLEARANCES TO COMBUSTIBLES

CLEARANCE TO COMBUSTIBLES (FREESTANDING)

- Side wall to unit

A- 6 INCHES (150 mm)

- Back wall to unit

B- 1 INCH

(25 mm)

- Corner to unit

C- 1 INCH

(25 mm)

- Mantle (Hearth Mount)

8 INCHES (

-Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and front must be protected by a non combustible material.

ALCOVE DIMENSIONS

Minimum Alcove width

36 inches (900 mm)

Minimum Alcove height

48 inches (1200 mm)

Maximum Alcove depth

30 inches (750 mm)

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.