Enviro EF-II I Troubleshooting, Do Not, The stove will not start, The stove will not light

Models: EF-II I

1 31
Download 31 pages 14.51 Kb
Page 24
Image 24
TROUBLESHOOTING

TROUBLESHOOTING

DO NOT:

-Switch the stove ON and OFF rapidly. This may cause current spikes, which could shorten the life of the electrical components.

-Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures.

-Remove any screws in the firebox without first lubricating them with penetrating oil.

TROUBLESHOOTING

What to do if:

1)The stove will not start

2)The stove will not light

3)The stove will not operate in the “AUTO” mode

4)The exhaust blower will not work

5)The convection motor will not function normally

6)The auger motor does not function normally

7)The Dial-A-Fire has no effect on the fire

8)The stove will not shut off

9)The stove keeps going out

10)Igniter will not function normally

**NOTE: All trouble shooting procedures should be carried out by qualified technicians.

1)The stove will not start

-Make sure the stove is plugged in and the wall outlet is supplying power.

-Push the auto/manual switch to manual, if the stove fails to start, unplug the unit and open the hinged side panels ( held tight with two screws).

-With the stove unplugged, examine all connections. Make sure they are firmly connected and that there are no exposed wires touching the stove (except the green chassis wire).

-Check the continuity and placement of connections against the wiring diagram in the back of this manual. Attempt to by-pass the switch by inserting a jumper wire between the dual black wires (middle of switch) and the single gray wire (left side of the stove) that attach to the back of the switch. Plug the stove back in. if the stove starts, replace the switch.

2)The stove will not light

-Check the ignitor by removing the burn pot liner when the unit is cold.

-Push the auto/manual switch to manual

-Observe the ignitor in the small tube to see if it glows within 3 minutes then return the switch to the “auto” position.

-If the ignitor does not come on, open the right hand side panel, remove the convection blower (held in by two bolts) and check connections of the harness then by-pass the 120°F (49°C) (N/C) temperature sensor.

-Push switch to manual to see if the igniter will heat up.

-If the igniter fails to come on, have your dealer or a qualified service technician replace the ignitor.

-If the ignitor comes on when the 120°F (49°C) is by-passed, replace the 120°F (49°C) (N/C) sensor.

24

Page 24
Image 24
Enviro EF-II I technical manual Troubleshooting, Do Not, The stove will not start, The stove will not light