3)The stove will not function in the “AUTO” mode when hot
-If the unit fails to operate,
4)The exhaust blower will not function normally
-Open the left side panel, check all connections against the wiring diagram.
-If all the connections are verified and the exhaust blower does not function at all , tap lightly on the exhaust motors end cap, this may loosen a tight motor.
-Apply 115V AC directly to the exhaust blower. If the motor does not run, replace the blower.
-If the motor runs, have your dealer inspect the wiring harness
5)The convection blower will not function normally
-Check all of the connections between the fan controller, switch, and the convection blower against the wiring diagram.
If the convection blower will not operate, Apply 115V AC to the motor directly, If the motor runs, Replace the fan controller. If the motor does not run, the convection blower has failed. Replace the blower.
6)the auger motor will not function normally
-Make sure the exhaust blower is operating.
-Make sure the
-Unplug the stove and open the side and back panels.
-Check all the connections to the auger motor,
-Check the condition of the Vacuum hose (located on the
-Check the manual reset button on the 200°F (93°C) temperature sensor. If this sensor has been tripped check the cause of the
-If the auger still does not operate then apply 115V AC directly to the auger motor. If the auger motor does not work. Replace the auger motor.
-
-Check the voltage across the load pins of the timing module. It should be around
-Check the Vacuum sensor by placing a jumper wire between the Blue and Black wires that are attached to the sensor. If the auger works, test to see if the exhaust blower is producing enough vacuum.
-To test the exhaust vacuum place a magnehelic gauge in the sensor end of the vacuum tube. It should read over 0.5. if the reading is good then replace the vacuum sensor.
-If the auger motor still does not work, then attempt to
-To test the
7)The Dial-A-Fire has no effect on the fire
-Make sure that all connections to the timer control module are correct and secure.
-Perform a resistance test to the
the two leads of the potentiometer. The potentiometer should have a range of 68k to 850k OHMS (plus or minus 10%)
-