OUTSIDE VERTICAL PIPE INSTALLATION

OUTSIDE VERTICAL PIPE INSTALLATION

To accomplish the above titled installation, follow steps 1 through 8 in the previous section (HORIZONTAL EXHAUST THROUGH THE WALL) and then finish it by performing the following:

9Install a tee with clean out on the outside of the house.

10Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.

11Secure the flashing as you go through the roof.

12Ensure that the rain cap is approximately 36” (900 mm) above the roof.