Installation

CLEARANCES TO COMBUSTIBLES - FREESTANDING:

When installing this unit on a combustible floor (eg. wood linoleum) a non-combustible hearth pad must be under the unit. The pad must extend at least the width of the appliance [22” (558 mm)] and at least the depth of the appliance plus 6” (150 mm) in front of the appliance [27 1⁄2” (699 mm)].

Side wall to unit

- 6 inches

(15 cm)

Back wall to unit

- 2 inches

(5 cm)

Corner to unit

- 2 inches

(5 cm)

Door front to edge of floor protection

 

 

- 6 inches

(15 cm)

36"

(91cm)

48"

(122 cm)

48"

(122 cm)

Figure 9: EF4 Freestanding Minimum Alcove Size.

These dimensions are minimum clearances but it is recommended that you ensure sufficient room for servicing, routine cleaning and maintenance.

 

���� ����

 

 

��

��

 

��� ���

 

��� ���

����

��

 

����

 

���� ���

 

 

 

 

��

 

 

���� ���

 

����� ����������

 

Figure 8: EF4 Freestanding Clearance to Combustibles.

Minimum Alcove width

- 36 inches

(91 cm)

Minimum Alcove height

- 48 inches

(122 cm)

Maximum Alcove depth

- 48 inches

(122 cm)

CLEARANCES TO COMBUSTIBLES - FIREPLACE INSERT:

Side wall to unit

- 9 inches

(22.9 cm)

Mantel projection

- 10 inches

(25.4 cm)

Mantel to top of unit

- 8 inches

(20.3 cm)

Facing on masonry fireplace edge

 

 

- 9 inches

(22.9 cm)

Minimum solid fuel burning fireplace opening:

Height

- 211⁄8”

(53.7 cm)

Width

- 22”

(58.9 cm)

Depth

- 211⁄2”

(54.6 cm)

 

10" (25.4 cm) Mantel

 

8"

 

(20.3 cm)

Wall

9"

Side

(22.9 cm)

 

Figure 10: EF4 Fireplace Insert Clearance to Combustibles.

13

Page 13
Image 13
Enviro EF4 owner manual Minimum solid fuel burning fireplace opening Height 211⁄8