![](/images/new-backgrounds/1054384/5438441x1.webp)
ADJUSTING THE VENTURI
•Remove the ash shelf by undoing the screw at each end, pull shelf towards you.
•Remove one screw from the cover plate located
below the ash shelf. Loosen the other screw (do not remove) swing the cover plate out of the way and tighten screw down to hold it in place.
•With along screwdriver rotate spring clips to open or close the shutter to the desired setting.
•The burner flame should be a bright yellow/orange when hot. Excessive blue is to lean and dark orange with soot is too rich.
FUEL CONVERSION
“Warning” This conversion kit shall be installed by a qualified service technician in accordance
with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or CO poisoning may result. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper or complete until the operation of the converted appliance is checked as specified in the owner’s conversion kit.
Please read and follow these instructions. Also please read the instruction guide lines provided by S.I.T on how to remove and install the
Carefully inspect all parts supplied with this conversion kit. Shut the gas off and disconnect the main gas line from the unit.
Open the door by unscrewing the ½” bolt on the right hand side of the stove. Lift door off the hinges mounted on the
Change the regulator on the front of the gas valve. (Follow the instructions provided by S.I.T)
To change the pilot orifice: First, remove the two (2)
(BE CAREFUL WHEN TIGHTENING THE PILOT FITTING, YOU COULD BREAK THE CERAMIC IGNITER ELECTRODE).
Remove the burner orifice with a ½” deep socket.
Install the new orifice supplied making sure that the orifice is in the correct location. Be sure to put a bead of pipe thread sealant or approved Teflon tape on the orifice before installing into the burner assembly.
Reinstall the burner tray, log set and door.
Re connect the gas line to the unit. Do a leak check using a soap and water solution or an approved manner on the gas supply line and the pilot tubing.
MAKE SURE that the sticker provided by S.I.T is installed to signify that this valve has been converted to a different type of fuel. Also make sure that the rating plate has a conversion label to show that this unit has been converted to a different fuel type.
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE REGULATOR IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER ON THE KNOB.
1 | 50% turn down | 1 Pilot assembly mounting gasket |
| |
screws | NATURAL GAS | PROPANE | ||
1 | Pilot Orifice. | .51mm | .35mm | |
1 pilot injector | Burner Orifice. | #42 dms | #53dms | |
1 | Main orifice | Venturi Settings | 1/16” min | ¼” min |
21