Enviro Indoor Gas Fireplace owner manual Qualified Installers Only, Maintenance And Service

Models: Indoor Gas Fireplace

1 32
Download 32 pages 50.52 Kb
Page 10
Image 10
QUALIFIED INSTALLERS ONLY

Maintenance And Service

QUALIFIED INSTALLERS ONLY

GLASS DOOR REMOVAL:

 

Open the door by removing the two (2)

 

5/16’’ bolts located at the top outside

 

corners of the glass frame (see Figure

 

8). Lift the bottom of the door up and

 

remove from unit (see Figure 9).

 

CAUTION GLASS MAY

 

SEPARATE FROM DOOR.

Figure : Top bolts for glass door.

Figure 9: Bottom hooks for

glass door.

BURNER & BLOWER REMOVAL:

 

1.Turn the unit off and allow the unit to cool completely.

2.Remove the fascia or louvers, open the door

(see MAINTENANCE AND SERVICE - GLASS DOOR

REMOVAL), and remove the log set.

3.Remove the log support tray by lifting the back of the tray up and pull it out from under the lip. Take care to not knock the pilot and the side brick panels.

4.Remove the centre and top brick panels (see

SECONDARY INSTALATION - REMOVING THE BRICK PANEL).

5.Turn gas supply off and remove gas connection. Disconnect the wiring from the side of the appliance.

6.Remove the three (3) T-20 screws just above the burner top on the back firewall (see Figure 10) and the two (2) screws on each side below the burner top. Carefully

Burner Top with

 

Grate Attached

 

Gas & Electrical

 

Tray Complete

 

Log Support

Blower / Fan

Tray

 

Figure 10: Removing burner and gas tray.

remove the complete gas and electrical tray assembly from the firebox, ensuring that no wires or gas lines are damaged.

7.Remove the blower and housing from the gas tray assembly by removing the three (3) fastening screws located on the back of the gas tray assembly. Pull the fan out from under the gas tray. Disconnect the wiring from the fan temperature sensor and remove fan.

8.Hook up wires from the new blower to main wiring harness and fan temperature sensor. Install the blower in the reverse order as described in Step 7.

6.Reinstall the completed gas tray into the firebox, being careful not to damage any wires or gas lines. Properly secure the gas tray assembly in the firebox. Hook up gas lines and wiring harness. Perform a gas leak check on all gas line with a soap and water solution or an approved method.

7.Return unit to original location if moved. Re-install the log support tray, the brick panels, the logset

(see SECONDARY INSTALATION - LOG SET AND EMBER INSTALLATION), the door and the fascia or louvers.

8.Check burner and blower assembly for proper operation.

Caution: Bleed lines before lighting and light pilot with door open.

10

Page 10
Image 10
Enviro Indoor Gas Fireplace owner manual Qualified Installers Only, Maintenance And Service