Enviro Indoor Gas Fireplace owner manual Secondary Installation, Removing The Brick Panel

Models: Indoor Gas Fireplace

1 32
Download 32 pages 50.52 Kb
Page 24
Image 24
REMOVING THE BRICK PANEL:

Secondary Installation

REMOVING THE BRICK PANEL:

The brick panel set is fragile, handle with extreme care.

The brick panel set comes pre-installed. The centre and top panel are the only panels that need to be removed if the complete gas and electrical tray assembly must be removed. The side panels may remain installed unless they are to be replaced.

1.Turn the unit off and allow the unit to cool completely.

2.Remove the fascia or louvers, open the door, and remove the log set.

3.Pull out the bottom of the centre panel while pushing up on the top panel.

4.With the center panel out, the top panel will easily come out. Just slide the top edge back out of the top lip in the firebox.

If the side and front panels must be removed, continue with steps 5, 6, 7, and 8.

5.Lift the front panel, located on the firebox bottom, from one end and remove the panel at an angle through the fire box opening.

6.Remove the log support tray by lifting the back of the tray up and pull it out from under the lip. Take care not to knock the pilot and the side brick panels.

7.Remove the two (2) T-20 screws holding the bottom of the baffle (shown in Figure 38).

8.Pull the panels out of the lips at the front of the firebox and carefully remove the panel from the unit (shown in Figure 39).

To re-install, follow the above steps in reverse. Ensure that the front and side panels are pushed as far forward as they can be before continuing with the installation.

Figure 37: Brick Panel Installation.

Figure 38: Brick Panel Installation.

Figure 39: Brick Panel Installation.

24

Page 24
Image 24
Enviro Indoor Gas Fireplace owner manual Secondary Installation, Removing The Brick Panel, Brick Panel Installation