Operating Instructions

For Your Safety, Read Safety Precautions And

Lighting Instructions Before Operating

TURN OFF UNIT:

Flip switch to OFF to turn off burners only.

If the fireplace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If the unit is going to be serviced, turn off the electrical power to the unit as well.

NOTE: When the unit is turned on for the first time, it should be turned onto high, with the fan OFF, for the first two to four hours. This will cure the paint, logs, gasket material, and other products used in the manufacturing process. It is advised that a door or window be opened, as the unit will start to smoke, which can irritate some people. After the unit has gone through the first burn, turn the unit OFF, including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good gas fireplace glass cleaner, available at your local Enviro dealer. See “DOOR REMOVAL” and “CLEANING THE GLASS” sections.

BLOWER SPEED:

The blower will come on only when the fireplace is up to temperature (approximately

 

 

 

��

20 minutes). Turning the fan control knob will change the speed of the fan. To turn

 

���

the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off (Figure 6).

 

 

 

It is advisable not to operate the blower below 1/3 speed as it puts a strain on the

 

 

windings of the blower and running the blower at lower speeds could also cause

 

��

premature fan failure.

 

 

 

 

 

 

Figure 6. Fan control.

NORMAL SOUNDS DURING OPERATION:

 

 

 

Table 2: Normal Sounds.

 

 

 

 

 

 

Component

Sound & Reason

 

 

 

 

 

 

Focus & Fascia

Creaking when heating up or cooling down.

 

 

 

 

 

Burner

Light pop or poof when turned off; this is more common with LP units.

 

 

 

 

Temperature Sensor

Clinking when it senses to turn the blower on or off.

 

 

 

 

 

 

Pilot Flame

Quiet whisper while the pilot flame in on.

 

 

 

 

 

Blower / Fan

Air movement that increase and decreases with the speed of the blower. The

 

blower is pushing the heat from the fireplace into the room.

 

 

Gas Control Valve

Dull click when turning on or off, this is the valve opening and closing.

 

 

 

 

ADJUSTING VENTURI AIR SETTINGS:

There is one venturi adjustment.

Use this venturi adjustment lever, shown in Figure 7, to

achieve a proper and efficient flame.

Adjust lever until the flame pattern is similar to Figure

36. Suggested pull out distances are 1⁄2” (13 mm) minimum for Natural Gas and 7⁄8” (22 mm) minimum for Propane.

Pull out the venturi adjustment to increase primary air at the venturi tube.

Push in the venturi adjustment to decrease primary air at the venturi tube.

Figure 7: Adjusting the venturi air setting.

8

Page 8
Image 8
Enviro Indoor Gas Fireplace owner manual Component Sound & Reason, Fan control