Trouble Shooting

Problem

Possible Cause

Solution

 

 

 

The main burner

The gas valve may not be on.

• Check that the gas control knob is in the “ON” position.

does not ignite

 

 

Thermostat is not calling for

• Adjust the thermostat several degrees above ambient temperature.

when called for.

heat.

 

 

 

 

 

 

 

Problem with gas valve.

• Use a DC voltmeter to measure the voltage across the TPTH and

 

 

TP terminals. Main operator voltage: Open circuit ≥ 325mV Closed

 

 

circuit ≥ 100mV

 

 

• If voltage is not present, check the control circuit for proper

 

 

operation.

 

 

• If proper control system voltage is present, replace the gas control.

 

 

 

Spark will not

Defective piezo ignitor.

• Check connections to ignitor.

light the pilot

 

• If ignitor connections are good but no spark, replace ignitor.

after repeatedly

 

 

Broken spark electrode.

• Check for broken ceramic insulation, replace electrode if broken.

pressing the

 

 

Misaligned spark electrode.

• If spark is not arcing from electrode to pilot, loosen the screws on the

spark ignitor.

 

 

pilot base adjust and tighten.

Pilot will not

Problem with thermocouple

• Check for proper connection of the thermocouple to the rear of the

remain lit.

circuit.

valve. If loose, fully tighten.

 

 

• Check pilot for full flame impingement around thermocouple. If flame

 

 

is too small, check gas pressure, adjust pilot rate screw, check pilot

 

 

head for damage.

 

 

• Check thermocouple voltage at valve. It must be greater than 5 mV.

 

 

If low, replace thermocouple.

 

 

 

 

Air in gas line (pilot dies while

• Bleed line.

 

knob is depressed).

• Check gas line pressure.

 

 

• Contact dealer.

 

 

 

Burners will not

Problem with thermopile

• Check gas line pressure .

remain lit.

circuit.

• Check for flame impingement on thermopile. If low, see “Pilot will not

 

 

remain lit”.

 

 

• Check thermopile for minimum of 300 mV when burner is switched

 

 

on.

 

 

• Check wiring to thermostat for breaks.

 

 

BV ONLY: Check for spillage at draft hood that may trip spill switch

 

 

 

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

 

 

 

 

Improper vent configuration

• Check vent configuration with manual.

 

 

 

 

Terminal may be recirculating

• Check to see if terminal is on correctly.

 

flue gases

• May need to install high wind termination cap.

 

 

• Contact dealer.

 

 

 

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

 

**Due to additives in gas, glass may get hazy during operation** Clean as needed.

 

 

 

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

 

 

 

Flames are

Flame impingement

• Check log positioning.

burning “dirty” or

 

• Increase primary air by opening the venturi shutter and/or by

sooting

 

opening the vent restrictor.

 

 

See also “Burners will not remain lit.”

 

 

 

Remote control

Problem with the remote

• One or more of the batteries are dead. See remote control

doesn’t work

 

instructions.

 

 

 

 

Problem with fireplace

• The on/off switch is turned to OFF.

 

 

• The gas control valve is turned to PILOT or OFF.

 

 

• The pilot has gone out.

 

 

 

BV ONLY:

• Air tight house.

• Supply make up air to the unit.

Insufficient air

• A vacuum in room due to

 

for combustion

other air-moving device.

 

 

 

 