A-4 Technical Specifications
R4C0910
Rev. C
A5 size SPEC.FM
1/12/00 Pass 3
LProof Sign-off:
SEI Y.Takasaki M.Fujimori
M.Fujimori
SEI M.Kauppi
Electrical
Note:
Check the label on the back of the scanner for voltage information.
Environmental
Note:
Specifications are subject to change without notice.
100 to 120 V AC 220 to 240 V AC
Input voltage range AC90 to 132 V AC198 to 264 V
Rated frequency 50 to 60Hz
Rated current 0.8A 0.4A
Power consumption Approx. 30W (operating)
Approx. 10W (standby)
Temperature:
Operation 5° C to 35° C (41° F to 95° F)
10° C to 32° C (50° F to 89° F)
when using the ADF
Storage –25° C to 60° C (–13° F to 140° F)
Humidity:
Operation 10% to 80%, without condensation
Storage 10% to 85%, without condensation
Operating conditions: Ordinary office or home conditions.
Extreme dust should be avoided.
Operation under direct sunlight or
near a strong light source should be