The first prompt you see is:

The data on the highest physical cylinder may be destroyed by this check.

Enter Y to start this check. Enter N to return to the menu.

Press Y and then Enter to continue with the test.

Error Codes and Messages

This table lists all the error codes and messages that may appear during diagnostics checks.

Error code

Message

System board

10180286 CPU ERROR

10227256 ROM CHECKSUM ERROR

1038254 TIMER COUNTER REGISTER ERROR

1048254 TIMER COUNTER ERROR

1058237 DMA CONTROLLER REGISTER ERROR

1058237 DMA REFRESH ERROR

106612 DMA PAGE REGISTER ERROR

1078042 TIMEOUT ERROR

1088042 SELF DIAGNOSTIC ERROR

1088042 WRITE COMMAND ERROR

1098259 INTERRUPT CONTROLLER ERROR

110146818 CMOS SHUTDOWN BYTE ERROR

111146818 CMOS BATTERY ERROR

112146818 CMOS CHECKSUM ERROR

11380286 INSTRUCTION ERROR

11480286 PROTECT MODE ERROR 1

11580286 PROTECT MODE ERROR 2

Memory

201MEMORY/PARITY ERROR