Configuration 29
5.1Configuring the Setup Parameters
Step | Display | Description | Text |
|
|
| Ref |
1 | CAL | Setup Program Parameters |
|
| BATCH | Set Batch Parameters | 5.2 |
| OPTION | Options (if installed) | 5.3 |
| TEST | Check Input Signals | 5.4 |
| END | Exit to normal operation |
|
| The following steps are displayed when CAL is selected. |
| |
2 | RESTOT | Reset all totals to zero. |
|
|
| To clear all totals (resettable and |
|
|
| accumulated) press the BATCH SET key |
|
|
| once. |
|
3 | SCALE | Scaling Factor. |
|
| Fact | Enter the Scaling factor | 3.3.1 |
|
| flowmeter. |
|
4F dPt Number of decimal points with which the Rate
is to be displayed between 0 to 0000.
5 | t.base | The Timebase with which the Rate is | 3.2.1 |
|
| calculated must be entered as: |
|
| 60secs | units/min |
|
| hours | units/hour |
|
| days | units/day |
|
| secs | units/second |
|
6FILTER The filter constant for filtering the rate display. 3.3.2
1 No filtering.
| to |
|
|
| 99 | Very heavy filtering. |
|
7 | TOTCON A division factor to convert the totals to | 3.30 | |
|
| different units from those used for rate (e.g., |
|
|
| gallons/min and barrels). |
|
| 1 | Rate and totals have the same engineering |
|
|
| units. |
|
| x.xxxx | Other factors can be programmed between |
|
|
| 0.01 and 2000. |
|
8t.dPt Number of decimal points with which the resettable total is displayed between 0 to 00.