5.1Configuring the Setup Parameters

Step

Display

Description

Text

 

 

 

Ref

1

CAL

Setup Program Parameters

 

 

BATCH

Set Batch Parameters

5.2

 

OPTION

Options (if installed)

5.3

 

TEST

Check Input Signals

5.4

 

END

Exit to normal operation

 

 

The following steps are displayed when CAL is selected.

 

2

RESTOT

Reset all totals to zero.

 

 

 

To clear all totals (resettable and

 

 

 

accumulated) press the BATCH SET key

 

 

 

once.

 

3

SCALE

Scaling Factor.

 

 

Fact

Enter the Scaling factor (K-factor) of the

3.3.1

 

 

flowmeter.

 

4F dPt Number of decimal points with which the Rate

is to be displayed between 0 to 0000.

5

t.base

The Timebase with which the Rate is

3.2.1

 

 

calculated must be entered as:

 

 

60secs

units/min

 

 

hours

units/hour

 

 

days

units/day

 

 

secs

units/second

 

6FILTER The filter constant for filtering the rate display. 3.3.2

1 No filtering.

 

to

 

 

 

99

Very heavy filtering.

 

7

TOTCON A division factor to convert the totals to

3.30

 

 

different units from those used for rate (e.g.,

 

 

 

gallons/min and barrels).

 

 

1

Rate and totals have the same engineering

 

 

 

units.

 

 

x.xxxx

Other factors can be programmed between

 

 

 

0.01 and 2000.

 

8t.dPt Number of decimal points with which the resettable total is displayed between 0 to 00.