Introduction HP289 2A
OPTIONS
MODEL 214D-( )-( )-( )-( )-( E )
OPTION ( E )
(H) 50 W HEATER (SPECIFY 12 VDC, 115 VAC OR 220 VAC)
(B) BACKLIGHTING DISPLAY
(C) CONFORMAL COATING
(CE) INTERFERENCE CE COMPLIANCE
(CEN) CENELEC, CSA NRTL/C AND SAA APPROVAL
(NTEP) WEIGHTS & MEASURES CUSTODY TRANSFER.
(AVAILABLE ON (LA) OR (LR) OPTIONS ONLY)
(UL) ELECTRICAL ETL (US) APPROVED TO UL508 & CSA
NOTES:
1. LCD DISPLAY 6 DIGIT 0.7" (17.8MM) HIGH, NON-VOLATILE TO TEN
YEARS.
2. TRANSDUCER SUPPLY 8-24 VDC @ 50 MA MAX., FIELD ADJUSTABLE.
3. 10 POINT LINEARIZATION WITH INPUT OPTIONS (LA), (LR) AND (Q).
THE (Q)OPTION CAN BE CONFIGURED WITH EITHER THE (LA) OR (LR)
OPTION. SINGLE POINT ‘K’ FACTOR WITH INPUT OPTIONS (1) AND (1H).
4. BOTH MAGNETIC COIL AND HALL EFFECT INPUTS ACCEPTED.
TEMPERATURE RANGE
5. (LR) RTD INPUT. . . . . . . . . . . . . . . . . . . . . . . . . . -148 TO +392 DEG. F.
(LA) 4-20 MA INPUT
GENERAL LIQUIDS . . . . . . . . . -459 TO +392 DEG. F.
PETROLEUMS. . . . . . . . . . . . . . -148 TO +392 DEG. F.
LPG. . . . . . . . . . . . . . . . . . . . . . . . -49 TO +140 DEG. F.
6. FOR BATCHES LESS THAN 15 SECONDS RESPONSE TIME IS LESS THAN
20MS WITH A SCALE FACTOR LIMITED TO 4000, ONE OR TWO STAGE
SHUTDOWN.
7. CAN CONTROL SINGLE OR DUAL STAGE SHUTDOWN VALVE.
8. PROGRAMMABLE TO COUNT UP OR DOWN FOR BATCH SIZE.