Interface Specifications

 

 

 

 

 

 

 

Signal

Return

Signal

Direction

Description

 

Pin

Pin

 

 

 

 

 

 

 

 

 

 

11

29

BUSY

OUT

A HIGH signal indicates that the printer

 

 

 

 

 

cannot receive data. The signal goes

 

 

 

 

 

HIGH in the following cases:

 

 

 

 

 

1) During data entry (ea. char. time)

 

 

 

 

 

2) During printing

 

 

 

 

 

3) When PAUSE botton is pressed

 

 

 

 

 

4) During printer-error state.

 

 

 

 

 

 

12

30

PE

OUT

A HIGH signal indicates that the printer is

 

 

 

 

 

out of paper.

 

 

 

 

 

 

13

-

SLCT

OUT

Pulled up to 5 volts through 3.3 Kohm

 

 

 

 

 

resistance.

 

 

 

 

 

 

14

-

AUTO

IN

When this signal is LOW, the paper is

 

 

 

FEED

 

automatically fed 1 line after printing.

 

 

 

R=T

 

(The signal level can be fixed to this by

 

 

 

 

 

setting DIP switch 2-4 to ON.)

 

 

 

 

 

 

15

-

NC

 

Not used.

 

 

 

 

 

 

16

-

GND

-

Logic ground level.

 

 

 

 

 

17

-

C H A S S I S -

Printer’s chassis ground, which is

 

 

 

GND

 

isolated from the logic ground.

 

 

 

 

 

 

18

-

NC

 

Not used.

 

 

 

 

 

 

19-30

-

GND

-

Twisted-pair return signal ground level.

 

 

 

 

 

 

31

16

INIT

IN

When this level becomes LOW, the

 

 

 

 

 

printer controller is reset to its power-up

 

 

 

 

 

state and the print buffer is cleared. This

 

 

 

 

 

level is normally HIGH; its pulse width

 

 

 

 

 

must be more than 50 microseconds at

 

 

 

 

 

the receiving terminal.

32ERROR OUT This level becomes LOW when the printer is:

1)in paper out state

2) PAUSE

3) in error state.

Technical Specifications 7-11