6.20Set Drying Time “DR” 04H 00H 00H m1 m2 m3
Format:
“DR” 04H 00H 00H m1 m2 m3
Parameters:
The m1, m2 and m3 are each one byte binary parameters. Parameter m1 indicates the state as follows:
Drying Position | m1 |
Per scan | 00H |
Per page | 01H |
Reserved | 02H - FFH |
The drying time by the following expression is set by the parameters m2 and m3. If m1=00H(drying per scan), the unit of time is m second. If m1=01H(drying per page), the unit of time is seconds.
(Drying Time) = ((m3 x256) + m2)
m1=00H: 0 ≤ (Drying Time) ≤ 10000 m seconds
m1=01H: 0 ≤ (Drying Time) ≤ 3600 seconds
Function:
-The default environment drying time is set.
-Stop on the position unit set by m1 for the time set by m2 and m3.
-If it is per page, it is waiting for setting time after received FF command. (If the FF command is not received, it doesn’t stop.)
-If parameter m1, m2, and m3 are out of range, this command is ignored and the existing setting is maintained.
-This command is only valid in remote mode.
Exception:
-If the banner mode is set, it processes after the LD command is executed and not after the FF command.
EPSON Imaging Technology Center | Page: 45 |
Revision: 1 (Date: 6/20/00) |
|