CHAPTER 2: S5U1C63000H2 PACKAGE
2.5 Setting the Dip Switch
The S5U1C63000H2 works with a personal computer that runs Windows as a host. With a general computer that meets the condition, the serial transfer rate set at the factory (9600 bps) is good for use. In case the rate is changed, the transfer rate between the host computer can be changed by this switch. The switch also sets a self diagnostic function, which is equipped in the S5U1C63000H2, working or not working at the power on. Figure 2.5.1 shows the dip switch.
— OPEN—1 2 3 4 5 6 7 8
|
|
|
|
| Fig. 2.5.1 Dip switch |
| <Setting baud rate> |
|
| |||
|
|
|
|
|
|
| SW4 | SW5 | SW6 | Baud rate setting | |
| OPEN | OPEN | OPEN | OPEN | 9600 bps, |
| OPEN | OPEN | ON | ON | 2400 bps, |
| OPEN | ON | OPEN | ON | 4800 bps, |
| OPEN | OPEN | OPEN | ON | 19200 bps, |
| OPEN | ON | ON | OPEN | 38400 bps, |
| Other settings |
|
| Do not set. | |
Note: The setting at the host end is recommended to be "9600 bps,
SW8 | Setting |
OPEN | Self diagnosis On |
|
|
ON | Self diagnosis Off (factory setting) |
|
|
Note: When the S5U1C63000H2 is started with the self diagnosis on, it takes approx. 5 minuets to be ready for use.
Open means that the switch lever is at upper side.
On means that it is at lower side.