CHAPTER 2: S5U1C63000H2 PACKAGE

2.5 Setting the Dip Switch

The S5U1C63000H2 works with a personal computer that runs Windows as a host. With a general computer that meets the condition, the serial transfer rate set at the factory (9600 bps) is good for use. In case the rate is changed, the transfer rate between the host computer can be changed by this switch. The switch also sets a self diagnostic function, which is equipped in the S5U1C63000H2, working or not working at the power on. Figure 2.5.1 shows the dip switch.

— OPEN—

1 2 3 4 5 6 7 8

 

 

 

 

 

Fig. 2.5.1 Dip switch

<Setting baud rate>

 

 

 

 

 

 

 

 

 

SW1–3

SW4

SW5

SW6

Baud rate setting

 

OPEN

OPEN

OPEN

OPEN

9600 bps, 8-bit character, 1 stop bit, no parity (factory setting)

 

OPEN

OPEN

ON

ON

2400 bps, 8-bit character, 1 stop bit, no parity

 

OPEN

ON

OPEN

ON

4800 bps, 8-bit character, 1 stop bit, no parity

 

OPEN

OPEN

OPEN

ON

19200 bps, 8-bit character, 1 stop bit, no parity

 

OPEN

ON

ON

OPEN

38400 bps, 8-bit character, 1 stop bit, no parity

 

Other settings

 

 

Do not set.

Note: The setting at the host end is recommended to be "9600 bps, 8-bit character, 1 stop bit, no parity".

<Setting the self diagnostic function>

SW8

Setting

OPEN

Self diagnosis On

 

 

ON

Self diagnosis Off (factory setting)

 

 

Note: When the S5U1C63000H2 is started with the self diagnosis on, it takes approx. 5 minuets to be ready for use.

Open means that the switch lever is at upper side.

On means that it is at lower side.

6

EPSON

S5U1C63000H2 MANUAL

 

 

(S1C63 FAMILY IN-CIRCUIT EMULATOR)