7.1 Diagnosis Test
The self diagnosis test is executed by setting SW8 of the DIP switch to OPEN and starting the debugger after power of the S5U1C63000H2 on.
Debugger for | S1C63 Ver | x.xx | ||
Copyright(C) | SEIKO EPSON | CORP. xxxx | ||
Connecting with ICE ............. |
| |||
DIAG test, please wait 5 | min. .. done ← ➀ | |||
Parameter | file | name | : xxxxxxxx.par | |
|
| Version | : xx | |
|
| Chip name : xxxxx | ||
CPU version |
| : x.x | ||
PRC board | version | : x.x | ||
LCD board | version | : x.x | ||
EXT board | version | : x.x | ||
ICE hardware version | : x.x | |||
ICE software version | : x.x | |||
DIAG test |
|
| : OK. |
Map ............................. | done |
Initialize ...................... | done |
> |
|
When an error is detected, the error message is output at the point of ➀ instead of "done". If an error message is output, stop using the S5U1C63000H2 because it may have a hardware failure.
This diagnosis test takes approx. 5 minuets for completion because of its precise inspection. Even in the free run mode, it takes approx. 5 minuets for the self diagnosis test before the target program is executed.
7.2 Warranty
Please refer to the warranty card attached to the unit for the warranty details.