Epson TM200 EMI and Safety Standards Applied, Reliability, Conditions of acceptability, Life

Models: TM200

1 57
Download 57 pages 55.72 Kb
Page 6
Image 6

TM200 Service Manual

EMI and Safety Standards Applied

These standards are only valid for products which bear a mark or statement on the main unit.

Europe:

CE marking: Directive: 89/336/EEC

 

 

EN55022:1998 Class A

 

 

EN6100-3-3:1995+A1:2001

 

 

EN55024:1998, including

 

 

IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5,

 

 

IEC61000-4-6, IEC61000-4-8,

 

Safety standards:

EN60950

North America:

EMI:

FCC Class A

 

Safety standards:

UL1950/CSA C22.2 No.950

Oceania:

EMI:

AS/NZS3548

Conditions of acceptability

1.This component has been judged on the basis of the required spacing in the Standard for Information Technology Equipment, including Electrical Business Equipment, UL 1950 and CSA22.2 No. 950. sub-clause 2.9, which would cover the component itself if submitted for Listing.

2.The terminals and connectors have not been evaluated for field wiring.

Reliability

Life:

Mechanism:

15,000,000 lines

 

Thermal head:

100 million pulses, 50 Km

 

Autocutter:

1,200,000 cuts

 

 

(End of life is defined to have been reached

 

 

when it reaches the beginning of the wear out

 

 

period.)

MTBF:

 

360,000 hours

 

 

(Failure is defined as a random failure

 

 

occurring during the time of the random

 

 

failure period.)

MCBF:

 

52,000,000 lines

 

 

(This is an average failure interval based on

 

 

failures relating to wear out and random

 

 

failures up to the life of 15 million lines.)

External Dimensions and Weight:

 

 

Height:

Approximately 138.7 mm (5.46")

 

Width:

Approximately 146.5 mm (5.77")

 

Depth:

Approximately 195 mm (7.68")

 

Weight:

Approximately 1.4 kg (3.08 lb)

 

 

(except for the paper roll)

- 4 -

Page 6
Image 6