![](/images/new-backgrounds/1119783/11978361x1.webp)
Epson STYLUS NX100/NX105/SX100/SX105/TX100/TX101/TX102/TX103/TX105/TX106/TX109/ME 300 |
| Revision A |
| ||||
| Table |
|
|
| |||
|
|
|
|
|
|
|
|
Occurrence timing | Detailed phenomenon | Defective |
| Check point |
| Remedy |
|
CR position | unit/part name |
|
|
| |||
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| 1. | Check if the grease is enough on the Guide Rail of the | 1. | After wiping the grease on the Guide Rail of |
|
|
|
|
| Lower Scanner Housing. (TBD) |
| the Lower Scanner Housing with a dry, soft |
|
• Operation | The Scanner Carriage Unit. does not | Lower Scanner |
|
|
| cloth, coat it with grease. (Refer to Chapter 6 |
|
• Anywhere | operate. | Housing |
|
|
| "MAINTENANCE" (p.116).) (TBD) |
|
|
|
| 2. | Check if the Scanner Carriage Unit is correctly | 2. | Reassemble the Scanner Carriage Unit |
|
|
|
|
| assembled. |
| correctly. |
|
|
|
| 1. | Check if the CR Motor Cable is connected to J7 on the | 1. | Connect the CR Motor Cable to J7 on the Main |
|
|
|
|
| Main Board. |
| Board. |
|
J7
• Power on | When turning on the power, the CR | CR Motor | |
• Anywhere | Motor does not operate at all. | ||
|
|
| CR Motor Cable |
|
|
|
|
|
|
|
2. | Check if the CR Motor Cable is damaged. | 2. | Replace the CR Motor with a new one. | |
|
|
|
|
|
3. | Check if the CR Motor operates. | 3. | Replace the CR Motor with a new one. |
TROUBLESHOOTING | Error Indications and Fault Occurrence Causes | 31 |