Thermador SEMW302, SEMW272 How to Obtain Service, Fahrenheit to Celsius, Voltage Change Option

Models: SEM302 SEM272 SEMW272 SEMW302

1 128
Download 128 pages 44.49 Kb
Page 36
Image 36
Do-It-Yourself Maintenance

Do-It-Yourself Maintenance

SEM/SEMW Oven Care and Use Manual

Do-It-Yourself Maintenance

Fahrenheit to Celsius

The oven has been preset to a Fahrenheit tempera- ture.

To change to Celsius, follow these steps:

I.Turn off ovens.

2.Touch and hold the START pad and then the CONVECTION pad at the same time for 3 seconds.

3.“F” appears in the temperature digits; release both pads.

4.Touch CONVECTION; “C” replaces “F.” This alternates when CONVECTION is touched.

5.To complete the change, touch START.

Voltage Change Option

The oven has been preset for 240 VAC. If your resi- dence has been supplied with 208 VAC, the oven voltage can be changed during installation.

1.Turn both ovens off. Touch OVEN OFF for each oven.

2.Touch and hold the START pad and the SELF CLEAN pad at the same time for 3 seconds.

3.“240” appears in the display. Release both pads.

4.Touch the SELF CLEAN pad. “240” is replaced with “208.” This alternates when SELF CLEAN is touched.

5.To complete the change, touch START.

Calibrating Oven Temperature

The electronic thermostat has been preset to 0°F and accurately maintains its setting. If the browning re- sults are too light or too dark for your preferences, you can raise or lower the setting.

To change calibration of oven temperature for single or upper ovens:

1.Turn off oven(s).

2.For single oven or upper oven, touch and hold the START pad and then touch the BAKE pad.

3.“0” (zero) appears in the temperature digits; re- lease all pads.

4.Touch BAKE and 0 changes in increments of 5 degrees each time it is touched. The maximum adjustment is ± 35ºF. In Celsius the range is ± 3ºC to 21ºC.

5.To complete the change, touch START.

To change calibration of oven temperature for lower oven on double ovens:

1.Touch the ROAST pad instead of the BAKE pad.

2.Continue with Steps 3 through 5, as described above.

NOTE: The available temperature range for this oven is 100ºF to 550ºF. This applies to all conven- tion cooking modes. A change in the cali- bration does not affect Dehydrate, Proof or Warm modes.

Volume

The volume of the beeps and beeps can be adjusted. Touch and hold the START pad and the PROBE pad for three seconds. Touch PROBE pad again to increase or decrease volume, from levels 1 to 3. Touch START to set volume selection.

How to Obtain Service

For authorized service or parts information, phone (800) 735-4328.

We want you to remain a satisfied customer. If a problem does come up that cannot be resolved to your satisfaction write to Thermador Customer Support Call Center,

5551 McFadden Avenue, Huntington Beach CA, 92649 or call: 1-800-735-4328.

Please include the Model Number, Serial Number and Date of Original Purchase and Installation.

34

Page 36
Image 36
Thermador SEMW302 manual How to Obtain Service, Fahrenheit to Celsius, Voltage Change Option, Calibrating Oven Temperature