2)Door Switch / Door Lock (00750) Replacement Procedure:

Unplug the unit.

Open the door remove the clamp to the door gasket in the front to access the door switch.

Unscrew the two screws to the door switch.

Replace with the new door switch and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Door Switch – Back View

Latch / Slider

4

 

 

 

IPX

5

 

 

 

 

 

IP

1

2

 

3

Micro Switch

MRL

MRN

 

 

Testing Procedure:

Cold Test:

1)Push the slider towards the left (referring to the position of the door switch as in the

figure) which will operate the micro switch and check for continuity between terminals 4 & 5.

2)If there is continuity door switch is good.

ePlease Note : The terminals 4 & 5 are not marked on the door switch it is just taken for explanation.

13

Page 13
Image 13
Equator MD3720CEE service manual Door Switch / Door Lock 00750 Replacement Procedure