11)Thermostat (00808) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

The fusible link is located on the heater housing as shown in the figure.

There is a small fuse inside the covering held by the clamp crewed on the housing. Unfix the screw and replace the same and do the wiring as before / below.

Fix all the parts back by following the reverse procedure.

Wiring: Thermostat

FD

FDX

Testing Procedure:

Cold Test:

FE

FEX

1)Check the continuity between the two terminals with black dots and the two terminals with the red dots, if there is continuity the thermostat is good.

22

Page 22
Image 22
Equator MD3720CEE service manual Thermostat 00808 Replacement Procedure, Fex