Equator MD3720CEE service manual Drain Pump 00776 Replacement Procedure

Models: MD3720CEE

1 30
Download 30 pages 61.49 Kb
Page 27
Image 27

16)Drain Pump (00776) Replacement Procedure:

Unplug the unit.

Make sure that there is no water in the unit. Carefully pull out the kick plate.

Tilt the unit towards the left and carefully lay down the unit on the side. Unfix the four leveling legs and remove the bottom panel.

Remove the clamps to the two hoses on the drain pump.

Unfix the 4 screws that hold the drain pump to the cabinet and replace the same. Do the wiring as before / below.

Fix all the parts back by following the reverse procedure.

Wiring: Drain pump

PSL

PSN

Testing Procedure:

Hot Test:

1)Set the washer knob to a position one click away from the off position and switch on the unit.

2)The drain pump should receive 115V AC supply and should start working.

3)If the drain pump is working it is fine or else the drain pump is bad.

27

Page 27
Image 27
Equator MD3720CEE service manual Drain Pump 00776 Replacement Procedure