AE/LZB 119 1902 R1A

FATAL_LCD_NOACK

HARDWARE

40

LCD did not ack message.

FATAL_LCD_HARD_FAIL

HARDWARE

41

LCD hardware is invalid.

FATAL_SCI_NOHEAP

HARDWARE

50

Serial communication interface out of heap (RAM

 

 

 

memory) space.

FATAL_DSP_NOACK

HARDWARE

60

DSP did not ack message.

FATAL_DSP_FIFOOVR

HARDWARE

61

DSP RX FIFO overflow.

FATAL_DSP_BADMSG

HARDWARE

62

Unknown message received from DSP.

FATAL_DSP_WRONGRESP

HARDWARE

63

Unexpected response received from DSP.

FATAL_DSP_TWOACKS

HARDWARE

64

Back-to-back ACKS received from DSP.

FATAL_DSP_NORESOURCE

HARDWARE

65

DSP queue is full.

FATAL_BL_NOHEAP

HARDWARE

91

Software memory error - Boot loader.

FATAL_BL_SCI_ATTACH

HARDWARE

92

Boot loader could not attach to SCI.

FATAL_RXSIF

HARDWARE

98

Phase samples are not changing.

Operational Software Fatal System Errors

Software fatal errors will automatically reset the radio. When the radio reset does not correct the problem, the radio must be serviced. Some of the errors listed below contain additional information to help resolve the problem.

Error Name

Message

Code

Description

RADC_PITD_ERROR

TRACKING

200

Personality tracking data error. Reprogram the

 

 

 

tracking data.

RADC_PIHW_ERROR

PERSDATA

201

Personality hardware data error. Reprogram

 

 

 

the personality.

RADC_FREQ_ERROR

FREQDATA

202

Personality frequency data error. Reprogram

 

 

 

the personality.

RADC_PITD_MALLOC_ERROR

SOFTWARE

203

Personality tracking data malloc error.

 

 

 

Reprogram the tracking data.

RADC_PITD_CKSUM_ERROR

SOFTWARE

204

Personality tracking data checksum error.

 

 

 

Reprogram the tracking data.

DACS_MODEM_FATAL_ERROR

SOFTWARE

301

Unable to correctly configure the modem for

 

 

 

EDACS operation. Reprogram the

 

 

 

personality.

DACS_RADC_FAILURE

SOFTWARE

302

Power cycle the radio.

DACS_TU_PUT_CISYSMSG_ERROR

SOFTWARE

303

CI message buffer is not enabled.

CONV_RADC_ERROR

SOFTWARE

400

Error calling RADC function. Power cycle the

 

 

 

radio.

CONV_PUT_UIMSG_ERROR

SOFTWARE

402

UI message buffer not enabled. Power cycle

 

 

 

the radio.

CONV_MODEM_RXOVR

SOFTWARE

403

Conventional DIGV modem overflow.

CONV_MODEM_RXAVR

SOFTWARE

404

Conventional DIGV modem underflow.

CONV_MODEM_FATAL_ERROR

SOFTWARE

405

Unable to correctly configure the modem for

 

 

 

conventional DIGV operation

CONV_PERS_ERROR

PERSDATA

407

Conventional personality error.

PI_NOPERS_ERROR

PERSDATA

500

Personality data is not present. Program the

 

 

 

personality.

PI_CRC_ERROR

PERSDATA

501

Flash personality CRC did not match

 

 

 

EEPROM. Reprogram the personality.

PI_DESC_CRC_ERROR

PERSDATA

502

Crucial personality data has incorrect CRC.

 

 

 

Reprogram the personality.