AE/LZB 119 1902 R1A

OPERATION

The LPE-200series of portable radios is designed for EDACS and conventional mode operation. When the unit is used in a trunked EDACS, the digital control channel is automatically monitored. When the user initiates a call, the unit sends a digital request through a control channel to the site controller. The site controller then assigns the calling radio and all members of the talk group to an available working channel. All operations in EDACS configurations are supported from a single-site system to wide-area trunking networks.

For more detailed operating instructions refer to Operator’s Manual AE/LZT 123 1868.

In the conventional mode, the Clear/Monitor button functions are:

1)to unsquelch the receiver to allow channel monitoring prior to transmission.

2)to remove Channel Guard Decoding from a channel.

Option Button

The weather-sealed option button activates one of a number of programmable software options selected

during PC programming. Programmable options include high/low power setting, keypad lock, LCD contrast, LCD and keypad back lighting.

CONTROLS

The radio features two rotary control knobs and an emergency button mounted on the top of the radio, with side-mounted push-to-talk, monitor/clear and option buttons. The front-mounted keypad has 6 buttons on the Scan and 15 buttons on the System (refer to Figure 1).

Power/Volume Knob

 

This knob controls power to the radio (On/Off) and

 

adjusts the Volume level of the speaker.

Control Knob

 

A 16-position rotary switch can select systems, groups

 

or conventional channels. The knob is fitted with a

 

variable hardware stop for radio customization.

Emergency Button

 

A recessed red button on the top of the radio initiates an

 

emergency alert to the dispatcher and talk group

 

members.

PTT Button

 

The weather-sealed Push-To-Talk (PTT) button must be

 

pressed before voice transmission begins. Pressing the

 

PTT button transmits the unit ID. In trunked mode, the

 

ID is transmitted upon depression of the PTT button.

Clear/Monitor Button

Power On/Off

Volume Knob

TX LED

Option Button

Clear/Monitor

Button

Push-To-Talk

(PTT) Button

System/Group/

Channel Knob

Antenna

Emergency

Button

Battery Release Button

In the trunked mode, the weather-sealed Clear/Monitor

button is used:

1)

to exit the current operation, removing all displays

 

associated with it and return the radio to the

 

selected talk group.

2)

to hang-up individual and telephone interconnect

 

calls.

Figure 1 - Controls (Top, Back and Left Panel Views)

8

Page 8
Image 8
Ericsson LPE-200 manual Operation, Controls