Installing the Equipment

 

 

 

Type of Connector

Description

 

 

 

 

ASI/SD-SDI/HD-SDI

75 Ω BNC connector for ASI or SDI (user selectable)

 

OUT 1 , 2 & 3

output feeds.

 

 

 

 

ASI INPUT

75 Ω BNC connector for ASI input feed.

 

 

 

 

CONTROL 1 & 2

8-way RJ-45 connectors for 10/100BaseT Ethernet

 

 

control and monitoring.

 

 

 

 

AC POWER

IEC100-120 V AC / 220-240 V AC power input.

 

 

 

 

TECHNICAL EARTH

Spade connector for unit technical earth.

 

 

 

 

2.5Connecting the Receiver to the Power Supply

Warning!

Do not overload wall outlets and extension cords as this can result in a risk of fire or electric shock.

As no mains switch is fitted to this unit, ensure the local power supply is switched OFF before connecting the supply cord.

The receiver is not fitted with an on/off switch. Ensure that the socket-outlet is installed near the equipment so that it is easily accessible. Failure to isolate the equipment properly may cause a safety hazard.

Connect the receiver to the power supply as follows:

1.Ensure the power supply is isolated and switched off.

2.Ensure the correct fuse type and rating has been fitted to both the equipment and the power cable.

3.Connect the lead to the receiver input connector and then to the power supply.

4.Switch on the power supply.

Table 5

Fuse Type and Rating

 

Power SupplyFuse Type and Rating

 

 

100-120 V AC / 220-240 V AC

IEC/EN 60127-2 Sheet 5

 

 

Bussmann S505/Littelfuse 215

 

 

2 A 250 V T HBC

 

 

 

Note: Refer to the Reference Guide for all power supply, fuse replacement, safety, EMC information and operating conditions.

EN/LZT 790 0009 R1A 2011-03-30

11 (44)