Quick Start Guide: Connect-Power-Configure

9.Set up Sync Count to Lock/Sync Miss Sample Size

10.Set up Sync Miss Limit.

A description of each of these User Settings can be found in the Reference Guide.

Note: If the unit has successfully locked to the incoming feed, then the TS Lock value in menu Input should be LOCKED.

3.4Selecting a Decode Service (Program)

To select a decode service:

1.Navigate to the Service menu. For incoming feeds containing only a single service the service may be selected automatically depending on service selection control.

2.If the service is NOT selected, press Edit and, using the S (Up) and T (Down) pushbuttons in the decode service sub-menu, scroll through the service name list.

3.Press Save to select the required service.

Note: If the unit has successfully selected a service, then the Service ID and Service name should be displayed in the Service menu.

3.5Configuring the Video Output

When configuring the Video Output, the following points should be observed:

The unit will automatically decode the first video component that it finds within the selected service.

An alternative video component may be selected from the service tab on the Web Control interface.

If the incoming video is successfully decoded then the status OK should be displayed on the appropriate page.

Successfully decoded High Definition video will be output from the connector marked Video Component.

Successfully decoded Standard Definition video will be output from the connector marked CVBS.

3.6Configuring the Audio Outputs

When configuring the Audio Outputs the following points should be observed:

EN/LZT 790 0009 R1A 2011-03-30

15 (44)