Essick Air ADA5112 installation instructions Table Of Contents, Safety Rules, Evaporative Cooling

Models: ASA35 AUA7112 ADA5112 ASA7112 ADA35 AUA5112 AUA51 ADA7112 ADA71 ASA5112 ASA71 AUA71 ASA51 ADA51

1 16
Download 16 pages 41.71 Kb
Page 1
Image 1
ADA35

Read Carefully All Of This Manual

Before Installing The Unit

Lea Con Cuidado Todo Este Manual Antes De

Models

Instalar La Unidad

ADA35

ASA35

 

 

Circle the model of your cooler and

ADA51

ADA5112

record the serial number below.

ASA51

ASA5112

Encierrre con un circulo el modelo de su

AUA51

AUA5112

enfriador y escribe el número de série abajo.

ADA71

ADA7112

 

 

Serial #

ASA71

ASA7112

Número De Série

AUA71

AUA7112

 

 

 

 

 

 

 

 

 

 

 

 

Table Of Contents

Safety Instructions

1

Specification Tables (Tablas de Especificaciones)

.......................... 5

Operation

1-2

Parts List (ADA35, ASA35)

6-7

Installation Instructions

2-3

Parts List (51

& 71

Series Down Discharge)

8-9

Electrical Wiring Diagram

3

Parts List (51

& 71

Series Side Discharge)

10-11

Maintenance Section

3-4

Parts List (51

& 71

Series Up Discharge)

12-13

Troubleshooting

4

Instrucciones en Español

13-16

Warranty

5

 

 

 

 

Vea el Español en el interior.

Read And Save These Instructions

Safety Rules

1.Read instructions carefully.

2.Electrical hook up should be done by a qualified electrician, so that all electrical wiring will conform to your local standards.

3.Always turn OFF POWER and UNPLUG motor and pump inside the cooler before installing or performing any maintenance.

4.Your cooler will run on either 120V or 240V A.C., single phase, 60 Hz (cycle) current.

5.Motor and pump have a grounded, molded plug and an automatic thermal overload switch which will shut motor off when it overheats. The motor will restart automatically when it cools down.

ASA35WARNING: To reduce the risk of fire or electric shock, do not use this fan with any “solid-state fan speed control device.”

Evaporative Cooling

Evaporative cooling is nature’s way of cooling. When air is moved over a wet surface, water is evaporated and heat is absorbed. When stepping out of swimming pool with the wind blowing, evaporative cooling makes you feel cool, even though the air may be warm.

This unit works on the same principle. Air is drawn across wet filter pads where the air is cooled by evaporation and then circulated throughout the building. It is this combination of cooled air and the movement of air over the skin which makes it feel cool.

Unlike refrigeration systems which recirculate the air, an evaporative cooler continually brings in fresh air while exhausting old air. You are completely replacing the air every 2 to 4 minutes by opening windows or doors or a combination of both. The air is always fresh, not stale, laden with smoke and odors as happens with refrigerated air conditioning.

Operation

To eliminate the delivery of hot air when starting the cooler, start the pump only for the first few minutes, then turn on the blower motor.

These coolers may be used without water for ventilation purposes. When outside air is cool (for example, at night) or when humidity is high the water pump can be turned off.

A cooler can also be installed with a thermostat and attic exhaust dampers to provide completely automatic operation.

110498-2

www.championcooler.com

12-09

Page 1