ETA Systems eta-ecm2063 L1 = 20A L2 & L3 = 20A, ETA-ECM2063 AC Power Distribution Sequencer

Models: eta-ecm2063

1 16
Download 16 pages 62.44 Kb
Page 11
Image 11
ETA-ECM2063 Load Wiring Option #3 - L1 = 20A, L2 & L3 = 20A

ETA-ECM2063

AC Power Distribution Sequencer

ETA-ECM2063 Load Wiring Option #3 - L1 = 20A, L2 & L3 = 20A

In this load/current wiring configuration the load section L1 (Channels 1 & 2) is connected to a single 20A AC Mains feed and load sections L2 & L3 (Channels 3, 4, 5, 6) are connected to second 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician.

1.Follow the steps listed in section “Accessing the Internal Wiring”

2.Choose the most convenient AC Mains inlet on the bottom of the raceway that allows for the easiest connection to the AC Mains line based on the layout of the installation.

3.Strip the wires 3/8".

4.Locate J25 L1 on the PCB. Remove the wire jumpers from P2 “N” and P3 ‘H”. Remove wire from push on spade lug, discard 2 wires.

5.L1 wiring: Locate J25 L1 on the PCB. Insert the 20A AC Mains wires into J25 L1 and secure by tightening the screws firmly.

Ground (Green GRN) wire into Pin 1 labeled “G”

Neutral (White WHT) wire into Pin 2 labeled “N”

Hot (Black BLK) wire into Pin 3 labeled “H”

6.L2 & L3 wiring: Locate J23 L3 on the PCB. Insert the second AC Mains wires into J23 L3 and secure by tightening the screws firmly.

Ground (Green GRN) wire into Pin 1 labeled “G”

Neutral (White WHT) wire into Pin 2 labeled “N”

Hot (Black BLK) wire into Pin 3 labeled “H”

7.Leave all other wires within the chassis alone and intact.

L1 = 20A

L2 & L3 = 20A

Internal Wiring Identification Label

(To be placed on Input Plate if configured in this manner)

 

CH1

 

 

CH2

CH3

 

 

 

CH4

CH5

 

 

CH6

 

K1

 

 

K2

K3

 

 

 

K4

K5

 

 

K6

 

CH6

 

 

 

 

 

 

 

 

 

 

 

 

PORT

CH5

 

 

 

 

 

 

 

 

 

 

 

 

CHANNEL CONTROL

CH2 CH3 CH4

 

 

 

 

 

 

 

 

 

 

 

 

 

CH1

 

 

 

 

 

 

 

 

 

 

 

 

 

L1

G

N

H

L2

G

N

H

 

L3

G

N

H

 

 

 

 

 

 

 

BLK Hot

 

 

 

BLK Hot

 

WHT Neutral

 

 

WHT Neutral

GND Green

 

GND Green

 

 

 

Installer’s Wiring

1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.

Telephone: 800-321-6699 • Fax: 800-996-3821

– 11 –

ETAsys.com

Specifications are subject to change without notice.

Page 11
Image 11
ETA Systems eta-ecm2063 L1 = 20A L2 & L3 = 20A, ETA-ECM2063 Load Wiring Option #3 - L1 = 20A, L2 & L3 = 20A, ETAsys.com