Euphonix MADI Converters Operation Manual

AM713 and MA703 Converters

 

 

 

 

2.4AM713 Rear Panel

Figure 2-2AM713 Rear Panel

Input Voltage Selector: This red switch allows the unit to operate in either 110/115 VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/230/240 VAC operation (see page 6). Units are shipped set and fused for 110/115 VAC.

Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard IEC power cords. The fuse tray contains both the active fuse and a spare fuse for 220/ 230/240 VAC operation. See page 6 for instructions on how to change the fuse for 220/ 230/240 VAC operation.

Analog Inputs (female XLR): 24 balanced, analog inputs on XLR connectors. Input sensitivity is set from the front panel.

Auxiliary Analog Inputs (female XLR): Two balanced analog inputs on XLR connectors. Input sensitivity is set from the front panel.

AES/EBU Digital Input (female XLR): Stereo AES/EBU digital input on one XLR connector. Functions in parallel with the auxiliary S/PDIF input and the two inputs should not be used simultaneously.

S/PDIF Digital Input (RCA): Stereo S/PDIF digital input on one RCA connector. Functions in parallel with the auxiliary AES/EBU input and the two inputs should not be used simultaneously.

AES Sync In (female XLR): Master clock input for the converter when using AES as Sample Rate Source.

AES Sync Thru (male XLR): Outputs the same signal connected to AES Sync In.

Word In (BNC): Master clock input for the converter when using Word Clock as Sample Rate Source.

Word Out (BNC): Outputs a Word clock signal synchronized to the Sample Rate Source. In the presence of an external Word clock input, this connector provides a regenerated version of that input signal. Without an external sample rate source, this connector outputs the internally generated clock signal.

12

Page 12
Image 12
Euphonix MD704, DM714, MA703 manual 2AM713 Rear Panel